C200 series bench scales service manual
- 11 -
SECTION 7 FACTORY MODE AND CALIBRATE
7.1 Enter factory mode
Hold MODE key, then press ON/OFF key to turn on the power, quantity display
window will show “M” mark, after some seconds, enter weighing mode (only weight
window on), enter factory mode.
7. 2 Type setting
After enter factory mode, hold MODE key until display show “
FUNC
”, release MODE
key, display show “
FO iSn
”, this is internal counts.
press ZERO/TARE key, display show “
F1 Grv
”, this is gravity Set the value of the
gravity. 0.96~1.04
press ZERO/TARE key, display show “
F2 D n”
press MODE key, display show “
Function
Describe
F0 isn
To see the count
F1 grv
Set the value of the gravity.
F2 d m
Sig rg
desc
0/0.0/0.00/0.000/0.0000/0.00000
Inc
1/2/5/10/20/50 set the divsion
cap
XXXXXX set the capacity
cal
Nonlin Normal calibration
Linear Linear calibration
Dual r
desc
0/0.0/0.00/0.000/0.0000/0.00000
inc
Div 1
1/2/5/10/20/50
Div 2
1/2/5/10/20/50
cap
Cap1
XXXXX set the capacity
Cap 2 XXXXX
cal
Nonlin Normal calibration
Linear Linear calibration
Use ZERO/TARE key to select type, To back up, press ADD after you select, press
MODE key to sure,
press MODE key, until dESC is displayed, this is the
decimal point parameter
To toggle between parameter name and current setting, press MODE
To change, press ZERO/TARE with current setting displayed
To back up, press ADD
Press ZERO/TARE to advance to next parameter, “inC”. This is the
display
Increment setting
.
To toggle between parameter name and current setting, press MODE
To change, press ZERO/TARE with current setting displayed
Summary of Contents for WorldWEIGH C200 Series
Page 1: ...V 1 19 C200 Series Bench Scales User s guide ...
Page 2: ......