B-TEK Scales Super Sack Instruction Manual Download Page 17

BTEK Super Sack Instruction Manual 

 

- 17 - 

Replacement Parts 

 

813-100094

     5K CLYDESDALE SCALE REPLACEMENT CELL 

813-100025

    10K CLYDESDALE SCALE REPLACEMENT CELL 

864-000008

     CLYDESDALE SUMMING BOARD/BOX 

911-000032

     CLYDESDALE LOAD CELL FOOT 

825-200006

     T403 PANEL MOUNT INDICATOR 

800-0002822

   POLE RELAY; DPDT 24VDC 10 A; 8 OCTAL PINS 

800-000139

     2-POLE BASE W/ OCTAL SOCKET 

800-000130

     ON DELAY TIMER 2 POLE 

899-100088    

 POWER SUPPLY (24VDC) FOR PRINTER, HEATER, FAN. 

873-000043    

 E-STOP RED 

100-161064

     TALL STACK LIGHT BRACKET TL30 

912-5591

         STACK LIGHT R/Y/G & BUZZER IP65 

100-160872

     MAIN CORNER UPRIGHT TUBE 

100-160902

     FILL TUBE 

 

For all other parts call your B-TEK scale representative. 

 
 
 

 
 
 

 

 

 
 
 

B-TEK Scales, LLC 

1510 Metric Ave. S.W. 

Canton, OH 44706 

Tel: 330.471.8900 

B-TEK.com 

 

Summary of Contents for Super Sack

Page 1: ...Instruction Manual B TEK Super Sack 7 23 V2023 1...

Page 2: ...2 Introduction 4 3 Super Sack Frame Assembly 5 4 Fit Assurance 6 5 Parts Inventor 7 6 Assembly Procedure 8 7 T403S Batch Controller Positioning the Scale 9 8 Pretesting Batching Guide 10 14 9 Wire Dia...

Page 3: ...ipment is safe for this equipment Allow only qualified personnel to work on electric electronic components Do not use this equipment for anything other than its intended use Ensure equipment is plugge...

Page 4: ...ty and the standard terms and conditions published by B TEK LLC If you have any questions regarding the Super Sack frame assembly or its components contact your local B TEK LLC scale representative o...

Page 5: ...Assembly Mounting Plate Height adjustable fill tube cross member assembly Main corner support tube Slide on base plate Clydesdale floor scale Bag fill tube Upper structure support cross member assembl...

Page 6: ...e please check the dimensions below to ensure that our super sack frame will fit your scale If you have a square symmetrical scale the base plates are the only assemblies that are critical for fit If...

Page 7: ...he diagram and parts list below 1 BTEK Clydesdale floor scale or existing floor scale Note If using an existing scale please confirm that it will fit using the dimensional chart on page 6 2 Base plate...

Page 8: ...t the quick release pin holes are lined up and positioned properly Next put the quick release pins and bolts in their designated holes Do not tighten anything at this time 3 Place the indicator bracke...

Page 9: ...n the bottom of the control panel box and tighten Use the wiring diagram located on the inside box to terminate your fill shutoff system components Note 120V The relays are triggered by low voltage DC...

Page 10: ...the three internal set point outputs Prerequisites Supplements Tech Guide CFG 108 Remote Switch Input Tech Guide CFG 110 Application Selection T403S Service and User Manuals Setup Menu Selecting Batch...

Page 11: ...Application The default settings for BATCH application are TYPE 2 SPEED MODE AUTO and DISP NET PREACT MANUAL and NEG FILL OFF External START STOP switches can be connected to INPUTS 1 2 or 3 and confi...

Page 12: ...ee falling material Manual entered preact values are used Auto initially uses entered preact values but automatically calculates and adjusts these values based on a percentage of the variance between...

Page 13: ...displayed 10 Press SELECT MANUAL is displayed 11 Press UNITS AUTO is displayed 12 Press ZERO PREACT is displayed 13 Press F1 until the indicator returns to normal operation Entering Setpoint and Init...

Page 14: ...ut1 and SP1 annunciator will shut off On the first Batch the indicator will use the manually entered Preact value to calculate the cutoff weight 3 After a scale motion settling delay to capture a stab...

Page 15: ...BTEK Super Sack Instruction Manual 15 T403S Batch Controller Diagram...

Page 16: ...BTEK Super Sack Instruction Manual 16 T403S Batch Controller with Alarm Timer...

Page 17: ...0 0002822 POLE RELAY DPDT 24VDC 10 A 8 OCTAL PINS 800 000139 2 POLE BASE W OCTAL SOCKET 800 000130 ON DELAY TIMER 2 POLE 899 100088 POWER SUPPLY 24VDC FOR PRINTER HEATER FAN 873 000043 E STOP RED 100...

Reviews: