![B-TEK Scales Centurion-AT Installation Manual Download Page 6](http://html.mh-extra.com/html/b-tek-scales/centurion-at/centurion-at_installation-manual_461276006.webp)
5
Choosing a Site
The first step in installing the scale is to choose an appropriate site. Pertinent steps in
choosing the site are:
- Ensure that the site has adequate approaching / exiting distance to comply with state
and local Weights and Measures regulations. Scale length and scale elevation
(maximum fall per foot allowance) will impact the total area requirement.
The site selected must meet state and local requirements. The following is taken directly
from Handbook 44 (H-44) issued by the National Institute of Standards and Technology.
UR.2.6.
Approaches
UR.2.6.1., Vehicle Scales - On the approach end or ends of a vehicle scale installed
in any one location for a period of six months or more, there shall be a straight
approach as follows:
(a) The width at least the width of the platform, and
(b) the length at least one-half the length of the platform but not required to be more
than 40 feet, and
(c) not less than 10 feet of any approach adjacent to the platform shall be constructed
of concrete or similar durable material to insure that this portion remains smooth
and level and in the same plane as the platform. However, rating of sufficient
strength to withstand all loads equal to the sectional capacity of the scale may be
installed in this portion. Any slope in the remaining portion of the approach shall
insure, 1) ease of vehicle access, 2) ease for testing purposes, and 3) drainage
away from the scale.
The scale drawings provided meet part (a) of this requirement. The site must be
located to meet parts (b) and (c).
The site should have adequate room for trucks to properly align with the platform before
pulling on. This is especially important if trucks must turn before driving onto the scale.
Trucks should remain on the scale for a period of time no longer than is necessary for
obtaining the vehicle weight. Drivers / passengers / pedestrians should not exit their vehicles
or use the scale platform as a walkway.
Some jurisdictions require that the scale platform be clearly visible from the location of the
scale instrument. Others will allow the use of closed circuit TV or even a voice intercom.
Obtain official approval before starting construction.