B meters RFM-RPT-3 Quick User Manual Download Page 2

 

RFM-RPT-3_868_ALIM_QUG

 

Quick User Guide 

v1.4 

RFM-RPT-3

 

 

 

 

                                              

 

WMBUS 868 MHz repeater 
 

Product description 

 

 

 

 

 

 

The  RFM-RPT-3  Wireless  MBUS  signal  repeater  is  a  device  that  allows  the  signal  repetition  of  the  wireless  M-bus  telegrams 
transmitted by the radio modules installed on the water meters, heat meters and heat allocators manufactured by B METERS. The 
device is also suitable for the repetition of radio signals transmitted by third party devices following WMBUS protocol T1 mode and 
complying the OMS specification. It must be configured by using the configuration software provided. This allows to set the working 
time window, the operating modes and it allows to test the telegrams detection in order to identify the best suitable installation 
position.  Please  refer  to  the  configuration  software  manual  for  a  detailed  description  of  the  configuration  features  and  options 
available.  
The RFM-RPT-3 can repeat the telegrams coming from another repeater of the same type (B METERS RFM-RPT3), allowing a multi-
hop system configuration (up to three consecutive repeaters).  
 

Package Content 

 

RFM-RPT-3 repeater 

 

Installation guide 

 

Technical data 

 

Battery power supply: 2 size D 20Ah 3,6V batteries included * 

 

Network  power  supply:  option  to  connect  a  power  supplier  4,5÷5,5  VDC,  50mA 
(WARNING:  the  power  supplier  must  comply  to  CE  marking  when  used  inside  EU 
community or need to be in compliance with national regulation of the country) 
For example B METERS cod. HS-POWER (accessory not included in this product) 

 

Antenna:  integrated  (with  SMA  connector,  it  can  be  replaced  with  remote 
compatible antenna, not supplied with this product) 

 

Radio Interface:  WMBUS EN13757-4  @868 MHz [10 mW] 

 

Battery life time: 5 years** 

 

Configuration:  must  be  carried  out  by  using  the  Config  RFM-RPT-3  configuration 
software (a magnet is needed for the configuration activation) 

 

Fixing method: on the wall 

 

Dimensions: 186 x 90 x 60 mm [H x W x D] 

 

Weight: 275g 

 

Radio Range: up to 300 meters*** 

 

Operating temperature: +1 ° C up to + 55 ° C 

 

Degree of protection: IP 63 

 
* Batteries are replaceable, spare batteries are supplied by B METERS, DO NOT REPLEACE 
the  battery  with  wrong  types.  To  replace  the  battery  without  losing  the  repeater 
configuration insert one new battery on the free battery connector, than remove the old 
ones and connect the second new battery on one of the free connectors. Disconnecting all 
the batteries from the board will cause the configuration lost, it will need to reconfigure 
the device. 
**  The  battery  life  strongly  depends  on  the  working  time  window,  set  during  the 
configuration process, and on the environmental conditions. Estimation of the battery life 
is given by the configuration software.  
*** Under optimal propagation conditions, the radio range depends on physical conditions 
(building constructions, climatic conditions, …) where propagation of the radio signal can 
therefore vary.  

 

Installation 

The  installation  is  provided  on  the  wall  by  fixing  it  with  screws.  It  is 
recommended  to  attach  the  RFM-RPT-3  repeater  in  a  vertical  position  and 
away from metallic masses or from any potential radio shielding at sufficient 
height  to  avoid  easy  tampering.  The  device  must  be  configured  with 
appropriate software for its operation. 
The installer has the task of checking the propagation conditions of the radio 
signal during installation (this can be assisted by a specific software function). 
If  it  is  necessary  to  connect  the  power  supply  to  the  product,  follow  the 
specifications in this manual and the polarities indicated in the product. 

Safety

 

 

During the installation process, handle the device with care, don’t crush, don’t bent, don’t exposure to electrostatic discharges 
which could damage permanently the device, do not install close to heat sources (radiators, conditioners, convectors etc..).

 

 

The RFM-RPT-3 repeater doesn’t contain hazardous materials in accordance with European directives 91/157/EEC, 93/86/EEC, 
and 2002/95/EC(RoHS). The device requires specific disposal on the end of its lifetime. Recycling is mandatory or recommended 
following the Directive RAEE 2012/19/UE inside European Union region, or anyway dispose in accordance with local laws and 
regulations. Do not burn, or undergo to high temperatures. 

 

 

The RFM-RPT-3 repeater works reliably in the environmental conditions specified in this manual. Any unauthorized intervention 
and/or modification may cause malfunctions or total damaging of the product. 

 
 

Warranty 

The warranty period is set at 24 (twenty-four) months from the date of the shipping of the material. Warranty is against defects in 
materials  or  workmanship  when  the  product  is  properly  used  and  maintained  in  normal  efficiency.  This  Warranty  is  valid  and 
enforceable in the country where the product was purchased. In the event that the product has been purchased in a country of the 
European Union, the warranty is still valid in all countries of the Community. 
 
To obtain warranty service, it is requested to comply with the following clauses:  

1.

 

Products must be delivered for repair at the expense of the customer.  

2.

 

The product warranty will be subject to the exhibition of a tax document (receipt, receipt or bill of sale), which attests 
to the date of purchase of the product.  

3.

 

The repair will not affect the original date of expiration of the warranty and will not involve the renewal or extension 
thereof. . 

4.

 

If at the time of the repair, the product has not any defect, it will be charged the costs of the technical analysis. 

5.

 

The warranty is void if the failure was due to: impacts, falls, misuse or abuse of the product, use of non-original batteries, 
accidents,  product  alteration,  replacement/detachment  of  seals  and/or  product  tampering.  The  same  also  does  not 
cover damage caused during transport if packages used are unsuitable.  

6.

 

The warranty is not covering the battery of the product. 

7.

 

The warranty does not cover the inability to use the product, other costs incidental or consequential damages or other 
expenses incurred by the purchaser. 

8.

 

The warranty doesn’t cover damage to the product caused by usage in any other way than described in this manual. 

 
 
 

Support on the products 

If  the  product  needs  to  be  sent  to  the  technical  assistance,  contact  your  dealer  or  contact  the  B  METERS  After  sales  service  at 

[email protected]

 
 

Declaration of Conformity 

Hereby, B METERS, declares that this RFM-RPT-3 is in compliance with the essential requirements and other relevant provisions of 
Directive 2014/53/EU. 
The complete declaration can be downloaded from the official website 

www.bmeters.com

 
 

Contact Info 

 

B METERS Srl 

 

Via Friuli 3 
Gonars (UD) – 33050  
Italy 

Tel: +39 0432931415 
Fax: +39 0432992661 
E-Mail (sales/informations): 

[email protected]

  

E-mail (technical support): 

[email protected]

 

Web: 

www.bmeters.com

 

 

 