background image

ver.1.3

Safety

• 

During the installation process, handle the device with care, don’t crush, don’t 

bent, don’t exposure to electrostatic discharges which could damage permanently 

the device, do not install close to heat sources (radiators, conditioners, convectors 

etc..).

• 

The 

IWM-LR4

  module  doesn’t  contain  hazardous  materials  in  accordance  with 

European directives 91/157/EEC, 93/86/EEC, and 2002/95/EC(RoHS). The device 

requires  specific  disposal  on  the  end  of  its  lifetime.  Recycling  is  mandatory  or 

recommended following the Directive RAEE 2012/19/UE inside European Union 

region, or anyway dispose in accordance with local laws and regulations. Do not 

burn or undergo to high temperatures.

• 

The 

IWM-LR4

  works  reliably  in  the  environmental  conditions  specified  in 

this  manual.  Any  unauthorized  intervention  and/or  modification  may  cause 

malfunctions or total damaging of the product.

Warranty

The warranty period is set at 24 (twenty-four) months from the date of the shipping of the 

material. Warranty is against defects in materials or workmanship when the product is 

properly used and maintained in normal efficiency. This Warranty is valid and enforceable 

in the country where the product was purchased. In the event that the product has been 

purchased in a country of the European Union, the warranty is still valid in all countries 

of the Community.

To obtain warranty service, it is requested to comply with the following clauses:

1. 

Products must be delivered for repair at the expense of the customer.

2. 

The product warranty will be subject to the exhibition of a tax document (receipt, 

receipt or bill of sale), which attests to the date of purchase of the product.

3. 

The repair will not affect the original date of expiration of the warranty and will not 

involve the renewal or extension thereof.

4. 

If at the time of the repair, the product has not any defect, it will be charged the 

costs of the technical analysis.

5. 

The warranty is void if the failure was due to: impacts, falls, misuse or abuse of the 

product, use of non-original batteries, accidents, product alteration, replacement/

detachment  of  seals  and/or  product  tampering.  The  same  also  does  not  cover 

damage caused during transport if packages used are unsuitable.

6. 

The warranty is not covering the battery of the product

7. 

The warranty does not cover the inability to use the product, other costs incidental 

or consequential damages or other expenses incurred by the purchaser.

8. 

The warranty doesn’t cover damage to the product caused by usage in any other 

way than described in this manual.

Support on the products

If the product needs to be sent to the technical assistance, contact your dealer or contact 

the B METERS After sales service at 

[email protected]

.

Declaration of Conformity

Hereby,  B  METERS,  declares  that  this 

IWM-LR4

  is  in  compliance  with  the  essential 

requirements and other relevant provisions of Directive 2014/53/EU.

The complete declaration can be downloaded from the official website 

www.bmeters.com

.

Contact Info

B METERS Srl

V

ia Friuli 3 

Gonars (UD) - 33050

Italia

Tel: +39 0432931415

Fax: +39 0432992661

E-Mail (sales/information): [email protected]

E-Mail (technical support): [email protected]

Web: www.bmeters.com

Quick User Guide – IWM-LR4_QUG 

Product description

The 

IWM-LR4

 module is a device that allows to transmit the reading data detected by 

WDE-K50 water meters manufactured by B METERS.

The device is already preconfigured in OTAA mode with preset keys. The keys (DevEUI, 

AppEUI and AppKey) are provided by BMETERS. For various needs, the modules can be 

configured in Activation By Personalization (ABP) mode via Android App. The application 

allows you to configure the module by choosing the different operating options. Please 

refer  to  the  configuration  app  manual  for  a  detailed  description  of  the  configuration 

features and options available.

Package Content

• 

IWM-LR4

 module with aluminum sticker already applied

• 

Mounting screw

• 

Anti-tampering sticker

• 

Installation guide

Technical data

• 

Working temperature: From +1°C to +55 °C

• 

Power supply voltage: Lithium battery 3V Li-SOCI2 – 2,4 Ah*

• 

Maximum battery duration: 10 years**

• 

Radio interface: LoRaWAN @868MHz [<25mW]

• 

Configuration: by using Android App + NFC Device

• 

Protection level: IP68***

• 

Transmission range: up to 5 Km****

• 

Dimensions: (l x d x h): 100 x 100 x 57 mm

• 

Weight: 167g

* Batteries are not replaceable, DO NOT ATTEMPT TO REPLEACE. Any attempt will void 

the warranty, moreover will irreversibly damage the device.

**  The  battery  life  strongly  depends  on  the  working  time  window,  set  during  the 

configuration process, and on the environmental conditions. Estimation of the battery 

life is given by the configuration software.

***IP68: maximum 24 hours of continuous submersion at 1 m depth

****Under  optimal  propagation  conditions,  the  radio  range  depends  on  physical 

conditions (building constructions, climatic conditions, …) where propagation of the radio 

signal can therefore vary.

Installation

The installation of the 

IWM-LR4

 module is allowed on the WDE-K50 meters only (from 

DN50 to DN200).

It  is  recommended  to  install  the

 IWM-LR4

  module  away  from  metal  objects  or  any 

potential radio shielding, in a place protected from tampering.

Provision the network server in which you want to integrate the sensor (AppEUI) and 

provide the application server with the unique DevEUI and AppKey keys. The installer has 

the task of checking the propagation conditions of the radio signal during installation.

Commissioning

Make sure that you have respected the installation conditions described above and that 

the module is positioned within the operating range of the LoRa gateway installed.

Remove the aluminum sticker applied on the bottom of the module and mount it on 

the meter as shown in the pictures. It is necessary to combine the hooks of the meter 

with the ones on the module [1]. With one hand keep the meter steady, with the other 

hand push the module gently towards the dial [2] and pull it in the direction shown by 

the arrow [3/4]. Proceed with the configuration of the K index (10 for all diameters up to 

DN125 included or 100 for diameters DN150 and DN200). Before proceeding with this, it 

is necessary to read the module to avoid incorrect LORA keys writing.

To initialize the module and send joining requests to the desired network server, it is 

necessary  to  let  the  inductive  index  of  the  dial  rotate  for  +/-5  revolutions  (on  the 

WDE-K50 models, this corresponds to +/- 50 or 500 liters, depending on the K value set). 

Verify then that the module has joined the network server in the next few moments.

Configuration by using Android App + NFC Device (for ABP mode or parameter modification)

to initialize the configuration process, place the NFC antenna of the android device near 

the module as shown in the picture. For the complete configuration instructions, please 

refer to the app manual.

To  avoid  possible  frauds  on  the  module,  it  is  recommended  to  tighten  the  mounting 

screw supplied and apply the adhesive seal.

IWM-LR4

 

   

LORAWAN radio module for B METERS water meters

Step 1

Step 2

Step 3

IWM-LR4

 installation:

IWM-LR4

 configuration / activation:

IWM-LR4

 adhesive seal mounting:

Configuration via NFC (optional)

Radio activation after +/- 5 index

revolutions

Before installing the 

IWM-LR4

:

Protective seal removal

NFC