IWM-LR3 - IWM-LR4
User Manual v1.0
21
4. Examples
GET FW VERSION (0x07)
R2H:
0x07, 0x00, 0x00, 0x00, 0x00
H2R:
0x07, 0x01, 0x00, 0x00, 0x04, 0x01, FW1, FW2, FW3
GET FW VERSION (0x07) with incorrect length
R2H:
0x07, 0x00, 0x00, 0x00, 0x01, 0x00
H2R:
0x07, 0x01, 0x04, 0x00, 0x00
RESET (0x0a)
R2H:
0x0a 0x00 0x00 0x00 0x01 0x04
H2R:
empty
SET_REVOLUTION_COUNTERS (0x16)
→
864 liters as initial consumption
R2H:
0x16 0x00 0x00 0x00 0x06 0x04 0x00 0x00 0x03 0x60 0x00
H2R:
0x16 0x01 0x00 0x00 0x00
SET_ALARM_PAR (0x26)
→
Temperature bytes enabled.
R2H:
0x26 00 00 00 09 04 00 00 00 01 00 00 00 00
H2R:
0x26 0x01 0x00 0x00 0x00
SET_ALARM_DATA (0X29) reset all alarms
R2H:
0x29 0x00 0x00 0x00 0x05 0x04 0x00 0x00 0x00 0x00
H2R:
0x29, 0x01, 0x00, 0x00, 0x00
Contact Info
B METERS srl
Via Friuli, 3 • Gonars 33050 (UD) • ITA
LY
Te
l: +39 0432 931415
Fax: +39 0432 9926
61
E-Mail (sales/info): [email protected]
E-Mail (support): [email protected]
Web: www.bmeters.com