background image

 

IWM-LR3_QUG 

Quick User Guide 

v1.2 

IWM-LR3

 

 

 

 

                                                         

   

 

LORAWAN radio module for B METERS water meters 

 

Product description 

 

 

 

 

The 

IWM-LR3 

module is a device that allows to transmit the reading data detected by the GMDM-I, 

GMB-RP-I and GMB-I water meters manufactured by B METERS. 

The device is already preconfigured in OTAA mode with preset keys. The keys (DevEUI, AppEUI and 

AppKey) are provided by BMETERS. For various needs, the modules can be configured in Activation 

By Personalization (ABP) mode via Android App. The application allows you to configure the module 

by choosing the different operating options.  Please refer to the configuration app  manual for a 

detailed description of the configuration features and options available.  

 

Package Content 

 

IWM-LR3 

module with aluminum sticker already applied 

 

Mounting screw 

 

Anti-tampering sticker 

 

Installation guide 

 

Technical data 

 

Working temperature: From +1°C to +55 °C 

 

Power supply voltage: Lithium battery 3V Li-SOCI

2

 – 2.4 Ah* 

 

Maximum battery duration: 10 years** 

 

Radio interface: LoRaWAN @868MHz [<25mW]  

 

Configuration: by using Android App + NFC Device 

 

Protection level: IP68*** 

 

Transmission range: up to 5 Km**** 

 

Dimensions: (l x d x h): 88 x 75 x 60 mm  

 

Weight: 124g 

 

* Batteries are not replaceable, DO NOT ATTEMPT TO REPLEACE. Any attempt will void the warranty, 

moreover will irreversibly damage the device. 

** The battery life strongly depends on the working time window, set during the configuration 

process, and on the environmental conditions. Estimation of the battery life is given by the 

configuration software. 

***IP68: maximum 24 hours of continuous submersion at 1 m depth  

****Under optimal propagation conditions, the radio range depends on physical conditions (building 

constructions, climatic conditions, …) where propagation of the radio signal can therefore vary.  

 

 

Installation 

The installation of the

 IWM-LR3 

module is allowed on the GMDM-I, GMB-RP-I and GMB-I meters only. 

It is recommended to install the 

IWM-LR3 

module away from metal objects or any potential radio 

shielding, in a place protected from tampering.  

Provision the network server in which you want to integrate the sensor (AppEUI) and provide the 

application server with the unique DevEUI and AppKey keys. The installer has the task of checking the 

propagation conditions of the radio signal during installation. 

 

Commissioning 

Make sure that you have respected the installation conditions described above and that the module 

is positioned within the operating range of the LoRa gateway installed.  

Remove the aluminum sticker applied on the bottom of the module to initialize it and send joining 

requests to the desired network server. Now connect the module on the meter as shown in the 

picture. 

It is necessary to pair the inductive index of the meter beneath the inductive sensor placed on the 

plate of the module. With one hand, keep the meter steady, with the other hand press then carefully 

the module and turn it in a counter-clockwise direction to lock it to the meter. 

Configuration by using Android App + NFC Device (for ABP mode or parameter modification): 

to initialize the configuration process, place the NFC antenna of the android device near the module 

as shown in the picture. For the complete configuration instructions, please refer to the app manual.

  

 

Check on the reading software/web application the correct data collection and check that no alarm 

is active. To avoid possible frauds on the module, it is recommended to tighten the mounting screw 

supplied and apply the adhesive seal. 

IWM-LR3

 

activation/configuration: 

 

 

 

Activation by removing the sticker 

Configuration via NFC (optional) 

 

 

 

 

 

 

 

 

IWM-LR3 

installation: 

 

 

 

 

 

Step 1 

Step 2 

Step 3 

 

 

 

 

 

 

IWM-LR3 

sealing: 

 

 

 

Safety

 

 

During the installation process, handle the device with care, don’t crush, don’t bent, don’t 

exposure to electrostatic discharges which could damage permanently the device, do not install 

close to heat sources (radiators, conditioners, convectors etc..). 

 

The 

IWM-LR3 

module doesn’t contain hazardous materials in accordance with European 

directives 91/157/EEC, 93/86/EEC, and 2002/95/EC(RoHS). The device requires specific disposal 

on the end of its lifetime. Recycling is mandatory or recommended following the Directive RAEE 

2012/19/UE inside European Union region, or anyway dispose in accordance with local laws and 

regulations. Do not burn or undergo to high temperatures.  

 

The 

IWM-LR3

  works reliably in the environmental conditions specified in this manual. Any 

unauthorized intervention and/or modification may cause malfunctions or total damaging of the 

product. 

 

 

Warranty 

The warranty period is set at 24 (twenty-four) months from the date of the shipping of the material. 

Warranty is against defects in materials or workmanship when the product is properly used and 

maintained in normal efficiency. This Warranty is valid and enforceable in the country where the 

product was purchased. In the event that the product has been purchased in a country of the 

European Union, the warranty is still valid in all countries of the Community. 

 

To obtain warranty service, it is requested to comply with the following clauses:  

1.

 

Products must be delivered for repair at the expense of the customer.  

2.

 

The product warranty will be subject to the exhibition of a tax document (receipt, receipt or 

bill of sale), which attests to the date of purchase of the product.  

3.

 

The repair will not affect the original date of expiration of the warranty and will not involve 

the renewal or extension thereof.  

4.

 

If at the time of the repair, the product has not any defect, it will be charged the costs of the 

technical analysis. 

5.

 

The warranty is void if the failure was due to: impacts, falls, misuse or abuse of the product, 

use of non-original batteries, accidents, product alteration, replacement/detachment of seals 

and/or product tampering. The same also does not cover damage caused during transport if 

packages used are unsuitable.  

6.

 

The warranty is not covering the battery of the product. 

7.

 

The warranty does not cover the inability to use the product, other costs incidental or 

consequential damages or other expenses incurred by the purchaser. 

8.

 

The warranty doesn’t cover damage to the product caused by usage in any other way than 

described in this manual. 

 

 

Support on the products 

If the product needs to be sent to the technical assistance, contact your dealer or contact the 

BMETERS After sales service a

[email protected]

 

 

 

Declaration of Conformity 

Hereby, B METERS, declares that this 

IWM-LR3 

is in compliance with the essential requirements and 

other relevant provisions of Directive 2014/53/EU. 

The complete declaration can be downloaded from the official websit

www.bmeters.com

 

 

 

Contact Info 

 

B METERS Srl 

 

Via Friuli 3 

Gonars (UD) – 33050  

Italy 

Tel: +39 0432931415 

Fax: +39 0432992661 

E-Mail (sales/informations)

[email protected]

  

E-mail (technical support)

[email protected]

 

Web

www.bmeters.com

 

 

 

Reviews: