background image

Hydrosplit_UI  - Hydrosplit User Interface

                                                                                                                  Softwa

re Manual – 

Manuale del Software – v1.0

 

 

 

 

 

 

 

                                                                                     

pag. 9 

 

2.3.

 

  

Configuration Setting panel – 

Pannello Configurazione

 

The information fields are divided in five categories: 

 

Energy meter, 

red

 

colored; 

 

Pulse inputs, 

green

 

colored; 

 

Pulse outputs, 

blue

 

colored; 

 

MBUS, 

orange

 

colored; 

 

Billing date, 

pink

 

colored. 

 

Buttons and functions description 

 

Buttons 

READ

 – it allows to show the data in the desired row. 

 

Buttons 

WRITE

 (not available for all versions)– it allows to set the calculator 

according to the parameter selected in the row show in the window. 

 
 

Buttons and functions description – Energy meter 
 

 

 

 

Pulse  Ratio

  –  Liter  /  pulse  ratio  for  the  “Flow  in”  pulse  input  (selectable 

between 0.1, 0.25, 1, 2.5, 10, 25, 100, 250 L/imp). Make sure that it is always 
compatible with the pulse ratio set on the flowmeter connected.  

 

Class

 – pulse system class (selectable between IA and ID); 

 

Energy unit 

– Measurement unit shown on the calculator display (selectable 

between MWh and GJ). 

 

Tampering contact (Enable / Disable) – 

it allows to select whether to enable 

I campi di informazione sono suddivisi in cinque categorie: 

 

Conteggio energetico, di colore 

rosso

 

Ingressi impulsivi, di colore 

verde

 

Uscite impulsive, di colore 

blu

 

MBUS, di colore 

arancione

 

Mese Fatturazione, di colore 

rosa

 

Descrizione pulsanti e funzioni

 

 

Pulsanti 

LEGGI

 – permette di visualizzare il dato della riga desiderata. 

 

Pulsanti 

SCRIVI

 (non disponibile per tutte le versioni) – permette di impostare 

il calcolatore secondo il parametro selezionato nella riga a video. 

 
 

Descrizione pulsanti e funzioni – Conteggio energetico

 

 

 

 

 

Peso  impulsivo

  –  valore  Litro  /  impulso  ingresso  impulsivo  “Flow  in” 

(selezionabile tra 0.1, 0.25, 1, 2.5, 10, 25, 100, 250 L/imp). Verificare che sia 
sempre compatibile col peso impulsivo del misuratore di portata collegato.  

 

Classe

 – classe sistema impulsi (selezionabile tra IA e ID); 

 

Unità  energia

  –  Unità  di  misura  mostrata  a  display  sul  calcolatore 

(selezionabile tra MWh e GJ). 

 

Contatto  frode  (abilita  /  disabilita) 

–  permette  di  scegliere  se  abilitare  o 

Summary of Contents for HYDROSPLIT-M3

Page 1: ...Hydrosplit User Interface Software Manual Manuale del software Hydrosplit User Interface...

Page 2: ...h Avvio del software 4 2 Software windows description Descrizione delle finestre del sistema 5 2 1 Home Home 5 2 2 Operation data panel Pannello dati operativi 6 2 3 Configuration Setting panel Pannel...

Page 3: ...Vista SP1 Windows XP SP3 Software Requirements Microsoft NET Framework4 0 Hardware Requirements Optical device mod B METERS UC CABLE Il software descritto nel presente manuale serve per leggere e modi...

Page 4: ...on of the mouse Extract all set the directory then press Extract In this file you ll find the exe file that should be launched double click with mouse left button Per avviare il software sar sufficien...

Page 5: ...ressing this button the calculator control panels will be started Language by pressing this button a drop down menu will appear Here you can select the software language La schermata visibile dopo l a...

Page 6: ...ows to reset the value in the selected row Warning this will be irreversible Once selected you ll be asked to confirm the operation All avvio dei pannelli di controllo per abilitare tutti i campi nece...

Page 7: ...er kW for cooling accounting Flow rate Actual Flow rate m3 h for cooling accounting Descrizione pulsanti e funzioni Riscaldamento Energia Calorie KWh totali contabilizzate dal calcolatore Volume Volum...

Page 8: ...Pulse input accounted volume m3 for the pulse input C1 C2 Pulse input accounted volume m3 for the pulse input C2 Descrizione pulsanti e funzioni Temperature attuali Pulsante LEGGI permette di visuali...

Page 9: ...nt unit shown on the calculator display selectable between MWh and GJ Tampering contact Enable Disable it allows to select whether to enable I campi di informazione sono suddivisi in cinque categorie...

Page 10: ...lect the start accounting value Tampering contact Enable Disable it allows to select whether to enable disabilitare il contatto antifrode Flow in sul calcolatore Modifica peso impulsivo Descrizione pu...

Page 11: ...it allows to show and modify the primary address set for heating units disabilitare il contatto antifrode C2 sul calcolatore Descrizione pulsanti e funzioni Uscite impulsive Potenza per impulso Calor...

Page 12: ...ne possibile selezionare il mese di fatturazione in cui il calcolatore memorizzer il consumo al giorno 1 2 4 Advanced Configuration Setting panel Pannello Configurazione Avanzata The information field...

Page 13: ...o Data fine vita mostra la data di fine ciclo di vita del dispositivo Installazione Mandata ritorno mostra il tipo di installazione consentito Password 1 mostra la password 1 Password 2 mostra la pass...

Page 14: ...ser manual of the device to check the prescription per each alarm code Controllare il manuale utente del prodotto per verificare le prescrizioni per ogni codice allarme Via Friuli 3 33050 Gonars UDINE...

Reviews: