background image

RELEASE DATE

7-11-14

REFERENCE

 

NUMBER

INS-1330.2

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

TENAYA2® ICEE™ SERIES 

Housing Installation

10.  Wipe O-ring clean of debris before re-inserting 

patented HydroLock™ plate on to junction box. 

Turn HydroLock™ plate clockwise to lock in place 

under pins.

B.  For a drive-over installation, fill the hole around 

the fixture housing to 15” below the finished 

grade with clean fill dirt and tamp carefully to 

prevent settling of fixture. Pour concrete and 

finish as required flush with the top surface of 

the Yellow Installation Cover. 

 Note: Drive-over rated for 35,000 lbs. GVW

A.  For soil installation, fill and tamp soil to the 

appropriate height leaving room for sod, 

pavers, etc. to be level with the top of the 

Yellow Installation Cover.

Soil installation is NOT Drive-over rated!

7.  Per DIG-IT Guide, backfill the gap between the 

bottom of housing and bottom of hole with 

sand for drainage.

8.  Rotate patented HydroLock™ plate counter 

clockwise to allow notch in HydroLock™ plate 

to clear pins on junction box. Pull to remove.

9.  Pull branch circuit wiring into junction box.  

Make watertight connections using waterproof  

wire connectors (provided) to leads on the 

interior patented HydroLock™ plate.

Concrete/Drive-over

Soil

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

Summary of Contents for TENAYA2 Series

Page 1: ...nd during servicing or relamping turn off power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may c...

Page 2: ...sufficient clearance to elevate housing to finished grade Top of yellow temporary cover level to finished grade 4 Raise housing on EMT to finished grade top of yellow temp cover Use bubble level on y...

Page 3: ...dard flat lens rated for 35 000 lbs GVW A For soil installation fill and tamp soil to the appropriate height leaving room for sod pavers etc to be level with the top of the Yellow Installation Cover S...

Page 4: ...SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS t P OPU CMPDL MJHIU FNBOBUJOH GSPN QSPEVDU JO XIPMF PS QBSU as this may cause an unsafe condition t FWFS PQFSBUF UIF GJYUVSF XJUI NJTTJOH PS EBNBHFE MFOT...

Page 5: ...illips screwdriver Leveling collar also allows for 30 of rotation to align faceplate screws with one another When collar is level and faceplate screw holes are aligned to final position secure the col...

Page 6: ...t in final position tighten two set screws 2 Install the faceplate using 3 16 Allen wrench BOE UPSRVF UIF GBDFQMBUF TDSFXT JO B DSPTT pattern to 25 in lbs Rock Guard w Optical Opening Rock Guard Half...

Page 7: ...ontrary to instructions may cause an unsafe condition The use of damaged components may cause an unsafe condition and void product warranty IMPORTANT SAFETY INFORMATION READ FOLLOW AND SAVE ALL SAFETY...

Page 8: ...nce to elevate housing to finished grade Top of yellow temporary cover level to finished grade 4 Raise housing on EMT to finished grade top of yellow temp cover Use bubble level on yellow temporary co...

Page 9: ...he Yellow Installation Cover Note Drive over rated for 35 000 lbs GVW A For soil installation fill and tamp soil to the appropriate height leaving room for sod pavers etc to be level with the top of t...

Page 10: ...D SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS t P OPU CMPDL MJHIU FNBOBUJOH GSPN QSPEVDU JO XIPMF PS QBSU as this may cause an unsafe condition t FWFS PQFSBUF UIF GJYUVSF XJUI NJTTJOH PS EBNBHFE MFO...

Page 11: ...otation to align faceplate screws with one another When collar is level and faceplate screw holes are aligned to final position secure the collar with UIF GPVS IFY OVUT QSPWJEFE 8 Install the faceplat...

Reviews: