background image

RELEASE DATE

12-13-16

REFERENCE

 

NUMBER

INS000933.1

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

Finished grade

8 3/4”

2 window
faceplate 
shown

Finished grade

8 3/4”

LINE

12V

FIXTURE

COM

Remote

Transformer

COM

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Optical opening on 

faceplate will align with 

alignment arrows on 

temporary cover

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Finished grade

Concrete

Wire nuts must 

clear opening

6” 

min.

10. Mount faceplate to collar using (2) #6-32 

screws (provided) with a 5/64” Allen wrench.

9.  Make watertight connections using waterproof 

wire connectors (By Others). Insert fixture and 

low voltage wire into Power Pipe™.

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

MINI-MICRO™ RECESSED UPLIGHT

Surface Mount Installation

 LED - For use with 12VAC 

remote transformer or magnetic 

transformers only. B-K Lighting cannot 

guarantee performance with third party 

manufacturers’ transformers.

4.  Align holes to final installation orientation. 

Arrows on temporary cover point towards screw 

location on faceplate for alignment purposes.

 

NOTE: Do not remove temporary cover until 

installation of faceplate.

Finished grade

12”

Finished grade

8 3/4”

LINE

12V

FIXTURE

COM

Remote

Transformer

COM

Screws on faceplate will 

align with alignment 

arrows on temporary 

cover

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Stability flange

Rebar or stake (by others)

Pea gravel or sand

Finished grade

Concrete

Finished grade

Concrete

Wire nuts must 

clear opening

6” 

min.

Finished grade

15”

6.  Remove temporary cover and pull out remote 

wiring.

2-1/4” O.D.

2-3/4” O.D.

2.  Loop minimum of 6” of wiring inside housing to 

allow for fixture service. 

 NOTE: 

 

Do not remove temporary cover! 

Finished grade

Wire nuts must 
clear opening

6” 

min.

Screws on faceplate will 

align with alignment 

arrows on temporary 

cover

7.  Access remote wiring inside housing. Make 

watertight connections using waterproof wire 

connectors (By Others). Wire nuts must clear 

opening. Insert fixture, wiring and connections 

into housing. 

See wiring diagram.

5.  Use a silicone based sealant (By Others) between 

fixture and mounting surface.

1.  Drill 2-1/4” diameter hole into mounting surface 

at uplight installation location as per lighting 

plan.

 

Do not exceed surface diameter, installation 

relies on surface mount collar resting on surface 

grade. Collar diameter is 2-1/4”. Surface mount 

flange is 2-3/4” diameter. 

 

Pull secondary wiring from remote driver.

3.  Place housing into hole. Surface mount collar 

should rest on finished surface grade.

 NOTE: 

 

Do not remove temporary cover! 

Core Drill Installation Instructions

Reviews: