1.  Mount  knuckle  onto  suitable  enclosure 

according to designed lighting plan.

2.  Secure ½” NPS stem to mounting option. Secure 

with provided locknut if applicable. 

3.  Make watertight connections from remote 

transformer  to  fixture  leads  using  waterproof 

wire connectors (By Others). 

See wiring 

diagram.

Fixture Installation with Standard Knuckle

4.   Use 5/32” Allen wrench to slightly loosen #10-

32  stainless  steel  black  oxide  socket  head  cap 

screw at the knuckle for aiming purposes. 

Tighten to secure desired location.

LINE

12V

Fixture

COM

Remote

Transformer

COM

MICRO NITE STAR™

Standard Installation 

& Low Voltage

WIRING DIAGRAM

 LED - For use with 12VAC 

remote transformer or magnetic 

transformers only. B-K Lighting cannot 

guarantee performance with third party 

manufacturers’ transformers.

 Low Voltage - For use with 12VAC remote 

transformer.