B-K lighting MB2 Installation Instructions Download Page 2

Installation Instructions

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900

 

www.bklighting.com • [email protected]

B-K LIGHTING

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

RELEASED

5-17-16

REFERENCE

 

NUMBER

INS-2505-00

Installation

1.  Remove  canopy  and/or  fixture  from  MB2  housing.  

Ensure  unused  tapped  holes  are  plugged  to 

maintain seal. Plugs are provided.

5.  Place  wire  connectors  and/or  power  supply 

inside  MB2  box,  then  secure  canopy  and/or 

fixture to MB2.

4.  Run  conduit  (By  Others)  to  MB2  box  location. 

Pull  wiring  to  MB2  box  location.  Use  waterproof 

wire  connectors  (By  Others)  to  connect  incoming 

primary wiring to power supply. Connect incoming 

ground wiring to ground conductor in housing. 

See 

wiring diagram.

WIRING DIAGRAM

LINE

(+)

FIXTURE

COM

WIRING DIAGRAM

POWER
SUPPLY

(-)

GROUND

GROUND  

MB2

Standard Installation

2.  To  prepare  MB2  for  mounting,  align 

mounting  brackets  on  back  of  box.  Brackets 

can  be  aligned  to  vertical,  horizontal  or  45° 

orientation.  Secure  with  mounting  screw 

using screwdriver.

3.  Mount  MB2  box  to  surface  using  mounting 

hardware  (Provided)  using  the  mounting 

brackets attached to back of MB2 box.

 

Alternative mounting methods may 

compromise integrity of MB2 against water 

intrusion and will void warranty.

 

NOTE: Surface conduit is a common entrance 

for water if not properly sealed. Seal connector 

threads and conduit with a suitable sealant  

(Teflon tape, adhesive, etc.). Sealing the conduit 

after knockouts are removed is required to 

maintain warranty.