background image

  & Low Voltage Halogen                                           

LT™/ LT-L™/ LT-T™

Installation Instructions 

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

Pea gravel or sand

Finished grade

Pea gravel or sand

Concrete or Soil

Finished grade

LINE

12V

FIXTURE

COM

Remote

Transformer

(by others)

COM

Finished grade

Optional 

Stability Flange

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

Pea gravel or sand

Finished grade

Pea gravel or sand

Concrete or Soil

Finished grade

LINE

12V

FIXTURE

COM

Remote

Transformer

(by others)

COM

Finished grade

Optional 

Stability Flange

Pea gravel or sand

Finished grade

Pea gravel or sand

Concrete or Soil

Finished grade

LINE

12V

FIXTURE

COM

Remote

Transformer

(by others)

COM

Finished grade

Optional 

Stability Flange

1.  Loosen #8-32 stainless steel set screw on cap  

using a 5/64” Allen wrench and remove.

THIS PRODUCT IS AVAILABLE WITH A FACTORY INSTALLED LED OR HALOGEN LAMP.

Halogen Lamp or LED Installation - If Required

DATE

11-30-16

REFERENCE

 

NUMBER

INS001109

3.  Place cap on fixture and tighten set screw. 

Tighten screw to 1/2 inch pounds.  Top of 

screw should sit flush with fixture cap.

 

  

 Warning:  Do not over tighten set screw.  

Doing so will compromise O Ring seal and 

will void warranty.

2.  Install lamp. For BKSSL: Pull the heat sink 

from the body to expose the LED board 

and Driver components. Utilize quick 

disconnects to change modular LED and 

driver components. Re-install the heat sink 

into body.

 

CAUTION…follow lamp manufacturers instructions. Do 
not touch lamp glass with bare skin. High temperature 
of lamp will cause skin oil to damage glass. Clean lamps 
with alcohol, if touched.

Halogen

BKSSL

Integral Transformer

1.   Pull branch circuit wires necessary for installation 

(By Others) through Power Pipe™.  Use waterproof 

wire connectors (By Others) to connect transformer 

primary leads to branch circuit wires. Connect 

incoming ground to ground wire provided in 

fixture body.

 See wiring diagram.

120V

12V

Fixture

COM

Remote

Transformer

COM

120V

12V

Fixture

COM

GROUND

Integral 

Transformer

COM

GROUND IN HOUSING

Pea gravel or sand

Finished grade

Pea gravel or sand

Concrete

Finished grade

Finished grade

Optional 

Stability Flange

120V

12V

Fixture

COM

GROUND

Integral 

Transformer

COM

GROUND IN HOUSING

2.  Insert wires, connectors and/or transformer into 

fixture base and attach to Power Pipe™.    Tighten 

three (3) #8-32 stainless steel round head Phillips 

screws at base to secure.

120V

12V

Fixture

COM

Remote

Transformer

COM

120V

12V

Fixture

COM

GROUND

Integral 

Transformer

COM

GROUND IN HOUSING

Pea gravel or sand

Finished grade

Pea gravel or sand

Concrete

Finished grade

Finished grade

Optional 

Stability Flange

120V

12V

Fixture

COM

GROUND

Integral 

Transformer

COM

GROUND IN HOUSING

120V

12V

Fixture

COM

Remote

Transformer

COM

120V

12V

Fixture

COM

GROUND

Integral 

Transformer

COM

GROUND IN HOUSING

Pea gravel or sand

Finished grade

Pea gravel or sand

Concrete

Finished grade

Finished grade

Optional 

Stability Flange

120V

12V

Fixture

COM

GROUND

Integral 

Transformer

COM

GROUND IN HOUSING

WIRING DIAGRAM

Integral 

Transformer

Fixed Stem And T-Housing Option Fixture Installation 

TRANSFORMER HOUSING MUST BE INSTALLED ABOVE GRADE. POWER PIPE™ IS LABELED AT GRADE LEVEL.

TRANSFORMER HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY

Reviews: