Installation Instructions

PROJECT:

TYPE:

RELEASE DATE

12-19-16

REFERENCE

 

NUMBER

INS-2388-00

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

10.  Remove any dirt or debris in O-ring groove near 

top of housing. Place O-Ring inside of groove.

Failure to clean groove of debris will cause 

fixture to fail and void product warranty. 

12. Install faceplate using 1/8” Allen wrench and 

hand-tighten the faceplate screws in a star 

pattern to 30 in-lbs. min.

 Do not use a power tool to install screws. Do 

not exceed 40 in-lbs.

11.  Attach fixture to installed driver assembly with 

quick disconnect.  

Summary of Contents for HP2 SERIES

Page 1: ...d during servicing or relamping turn off power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition The use of damaged components may cause an unsafe condition and void product warranty IMPORTANT SAFETY INFORMATION READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS...

Page 2: ...ousing is level tighten screws on Stability Flange to secure housing to EMT Remove excess EMT as needed 7 Per DIG IT Guide backfill the gap between the bottom of housing and bottom of hole with sand for drainage Housing Installation Threaded Entry Side Flats 1 Connect branch conduit connectors By Others to the junction box using either the threaded conduit entries on the bottom of the junction box...

Page 3: ...Patented HydroLock Barrier plate with quick disconnect WIRING DIAGRAM LINE HYDRO LOCK PLATE COM GROUND LINE COM GROUND 1 Remove temporary cover 2 Pull primary branch circuit wiring and dimmer wiring into junction box 3 Make connections using silicone filled wire nuts provided to leads on the bottom of Patented HydroLock Barrier Plate Assembly See wiring diagram 5 Turn HydroLock Barrier Plate clock...

Page 4: ... REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS 10 Remove any dirt or debris in O ring groove near top of housing Place O Ring inside of groove Failure to clean groove of debris will cause fixture to fail and void product warranty 12 Install faceplate using 1 8 Allen wrench and hand tighten the faceplate screws in a star pattern to 30 in lbs min Do not use a power tool to in...

Page 5: ...come extremely hot Do not touch hot lens or fixture body Do not touch the lamp at any time Use a clean dry soft cloth to handle the lamp Oil from skin may damage the lamp and cause it to rupture Replace lamp only with correct wattage and type of lamp marked on fixture label All gaskets O rings and sealing surfaces must be kept clean during installation and service failure to do this may cause an u...

Page 6: ...person in a manner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out pow...

Page 7: ...ner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or c...