background image

RELEASE DATE

01/18/2021

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

REFERENCE NUMBER

INS-2841-00

2.  Use a 5/16” allen wrench to loosen three 

(3) #8-32 stainless steel set screws 

(do not 

remove set screws from fixture)

. Remove 

anchor base from the fixture.

Finished Grade

1.  Drive the stake into the ground with a mallet or 

a small sledge hammer (by others). Make sure 

the top is flush with the finished grade.

 Remote Installation

3.  Attach the anchor base to the threads on the 

stake. Make sure the stake is secured in the 

ground.

 

6.  Make watertight connections from remote 

transformer to fixture leads using waterproof 

wire connectors (by others). 

See wiring 

diagram.

Finished Grade

4.  Pull low voltage, typically direct burial cable 

throught the stake center where the hole is 

located to make the connect with the fixture.

 Ground wire connections is based off of 

local code requirements.

7.  Install fixture onto anchor base. 

Do not pinch 

wiring.

 Secure fixture by tightening three (3) 

stainless steel set screws on fixture knuckle 

using a 5/64” allen wrench. 

Do not overtighten 

set screws.

Remote

Transformer

Low Voltage

 Installation Instructions

          GARDEN STAR (GR)

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION 

INSTRUCTIONS

LINE

12V

Fixture

COM

Remote

Transformer

COM

WIRING DIAGRAM

For use with 12VAC remote transformer.