![background image](http://html1.mh-extra.com/html/b-k-lighting/bkssl-mini-micro-ilume/bkssl-mini-micro-ilume_installation-instructions_3097773002.webp)
RELEASED
11-21-16
REFERENCE
NUMBER
INS001080.2
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
PROJECT:
TYPE:
MINI-MICRO ™ iLUME™
Flush Mount Installation
Align holes
with window
orientation
2 window
faceplate
shown
4. Fit flush mount collar into hole so it is flush with
finished surface. Wipe off any excess adhesive.
NOTE: The optical opening on faceplate will
align with the threaded holes in the flush
mount collar.
2 window
faceplate
shown
Finished grade
8 3/4”
LINE
12V
FIXTURE
COM
Remote
Transformer
COM
2 window
faceplate
shown
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Finished grade
Concrete
8. Remove temporary cover and pull out low
voltage wire.
Wire nuts must
clear opening
6”
min.
Finished grade
6”
min.
Finished grade
Wire nuts must
clear opening
6”
min.
Finished grade
8 3/4”
5. Supply low voltage wiring necessary for
installation (By Others). Loop minimum of 6” of
low voltage wire behind mounted collar to allow
for fixture service.
NOTE: Leave sufficient wire length in hole for
future service.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
Align holes
with window
orientation
2 window
faceplate
shown
7. Mount faceplate to collar using (2) #6-32 x 5/8”
flat head cap screws (provided) with 5/64” Allen
wrench.
2 window
faceplate
shown
Finished grade
8 3/4”
LINE
12V
FIXTURE
COM
Remote
Transformer
COM
2 window
faceplate
shown
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Finished grade
Concrete
8. Remove temporary cover and pull out low
voltage wire.
Wire nuts must
clear opening
6”
min.
Finished grade
6”
min.
Finished grade
Wire nuts must
clear opening
6”
min.
Finished grade
8 3/4”
6. Pull low voltage wire through flush mount collar
and make two low voltage connections using
proper wire connectors (By Others). Insert wires
and fixture back into hole.
Finished grade
8 3/4”
2 window
faceplate
shown
Finished grade
8 3/4”
LINE
12V
FIXTURE
COM
Remote
Transformer
COM
2 window
faceplate
shown
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
WIRING DIAGRAM
Align holes
with window
orientation
2 window
faceplate
shown
Align holes
with window
orientation
2 window
faceplate
shown
Align holes
with window
orientation
2 window
faceplate
shown
1. Drill 2-1/4” diameter hole, 3” deep minimum, for
fixture.
2. Prepare epoxy according to instructions on
packaging.
3. Use mixing stick to apply the epoxy to the interior
of the 2-1/4” hole as shown.