![background image](http://html1.mh-extra.com/html/b-k-lighting/artistar-integral/artistar-integral_installation-instructions-manual_460882004.webp)
ArtiStar™ TR
Power Pipe
™
Installation
Power Pipe Mounting Option
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
4. Back fill with pea gravel or sand prior to pour.
8. Tighten three (3) #8-32 stainless steel round
head Phillips screws at base and 1/4”-28
stainless steel black oxide socket head screw at
the knuckle to secure all aiming positions.
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
5. Pour concrete (By Others).
Label on Power Pipe™ indicates installation
depth with finished grade.
WIRING DIAGRAM
6. Use waterproof wire connectors (By Others) to
connect driver primary leads to branch circuit
wires. Connect incoming ground to ground
wire provided in fixture body. See wiring
diagram.
RELEASED
1-18-17
REFERENCE
NUMBER
INS-2120-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
7. Insert wires, connectors and driver into fixture
base and attach to Power Pipe™. To aim fixture,
use 3/16” Allen wrench to slightly loosen ¼”-28
stainless steel black oxide socket head screw at
the knuckle for vertical aiming purposes. Rotate
fixture to aim to desired horizontal location.
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
3. Pull branch circuit wires necessary for
installation (By Others) through Power Pipe™.
Allow for additional cable to make connections
to fixture lead and future service. Place Power
Pipe™ in hole. Do not cut PVC.
Finished grade
Pea gravel or sand
Concrete
Finished grade
Finished grade
Stability Flange
Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
Pea gravel or sand
Finished grade
Pea gravel or sand
Concrete or Soil
Finished grade
LINE
12V
FIXTURE
COM
Remote
Transformer
(by others)
COM
Finished grade
Optional
Stability Flange
2. Slide optional Stability Flange onto Power
Pipe™. Use optional Stability Flange to aid in
installation of Power Pipe™.
1. Excavate trench according to designed lighting
plan. Dig hole a minimum of 18” deep and 10”
wide to accommodate Power Pipe™ at desired
fixture location(s).
All line voltage connections must be made
in compliance with the National Electrical
Code. Failure to do so will void warranty.
LINE
(+)
FIXTURE
COM
WIRING DIAGRAM
POWER
SUPPLY
(-)
GROUND
GROUND IN HOUSING
DRIVER HOUSING MUST BE INSTALLED ABOVE GRADE. POWER PIPE™ IS LABELED AT GRADE LEVEL.
DRIVER HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY
ArtiStar™ Integral
Solid State LED
Installation Instructions