Installation and Operating Instruction for
B.E.G.
-Occupancy detectors
PD4-M-DIM-C-SM/-FC
LUXOMAT
®
PD4-M-DIM-
Corridor
GB
4. DIP switch functions
DIP-
switch
ON
OFF
1
Semi automatic mode
Fully automatic mode
2
LED OFF
LED ON
3
Corridor mode
Standard mode
DIP
OFF
ON
1
2
3
3. Position DIP-switches
The DIP switch set-
tings are overriden
using the remote
control.
Surface mounting
1
2
3
OFF
ON
VA
LED
HA
COR
ON
OFF
DIP
7. Option:
Wall bracket for remote
control IR-PDim
IR-PDim
5. Putting into operation / Settings
Initialization
In the first 60 seconds after connecting the power supply the
LUXOMAT
®
PD4-M-DIM-C will go through a self test cycle. During this time the device
doesn´t respond to movement, but will stay on the status depending on the
selected initialization mode on or off (INI OFF or ON).
Warning: In the Ini-OFF mode, does not switch on lights at power start
up. After 60 seconds, detector would switch on lights on upon detecting
movement.
Follow-up time for light control
The time can be set infinitely variably at between
1 and 30 minutes.
Symbol
TEST
: Test mode (Every movement switches on the
light for a period of 1 second, switching it off for a period of
2 seconds after that regardless of the level of brightness)
Twilight-switch for light control (relay 1)
The switch-on value for the light can be set at between 10
and 2000 Lux. Using the rotary control, the luminance set
points can be set as desired.
Symbol :
Night-time operation
Symbol
: Daytime/Night-time operation
Orientation lighting
This rotary controller serves to determine the working time of
the orientation lighting (fixed to 20 %).
“ON” for permanent orientation lighting.
“OFF” for deactiviation of orientation lighting.
Pulse spacing PD-Slave
2 or 9 seconds can be set for the pause between 2 pulses
sent to the master. The setting can be made with activated (
) or deactivated ( ) LED indicator.
For devices with a separate slave input, 2 sec. can be set.
9s
2s
LED ON
LED OFF
25 22
18
16
10
3
1
TEST
6
30
R1
120 6050
40
30
15
10
A
16 10
5
2
1
30
15
TEST
2000
1200
600
200
40
5
60
5
10
30
50
ON
OFF
6. Settings carried out using remote
control (optional)
Remote control
LUXOMAT
®
IR-PDim
1. Check Battery:
open battery compartment by pressing the
plastic springs together and removing the
battery-holder.
2. IMPORTANT
Please pay attention, that the setting is
Potentio-meter 1 at “TEST” and Potentiometer
2
not
at “SUN”. All values which have
been programmed using the remote control
will be deleted in the event of power failure
in the position “TEST/SUN”. Please switch
Potentiometer 2 over to “MOON” or any
other value.
Caution:
Settings with remote control supersede the
settings by courtesy of potentiometers.
1
1
2
2
25 22
18
16
10
3
1
TEST
6
30
R1
120 6050
40
30
15
10
A
16 10
5
2
1
30
15
TEST
2000
1200
600
200
40
5
25 22
18
16
10
3
1
TEST
6
30
R1
2000
1200
600
200
40
False ceiling mounting
1
2
3
ON
OFF
DIP
1. Mounting preparations
Work on the 230 V mains supply
may only be carried out by quali-
fied professionals or by instructed
persons under the direction and
supervision of qualified skilled
electrical personnel in accordance
with electrical regulations.
Disconnect supply before installing!
The device is not suited for safe
disconnection of the mains supply.
When in Master/Slave mode of op-
eration, the Master-appliance must
always be installed at the location
where there is least daylight.
2a. Installation of the LUXOMAT
®
PD4-DIM-C-SM
The detector must be in stalled on a solid and level
surface. The circular cover ring must be removed
prior to assembly. To do this, twist the lens (C) an-
ticlockwise through approximately 5° and lift off.
Having connected up the wires in accordance
with regulations, secure the detector with 2
screws. After installation replace the lens and
lock (turn clockwise). Mains to be connected
.
ATTENTION:
For maximum sensitivity the detec-
tor-, lens- and corridor-axis must match.
C
open
close
opened
closed
2b. Montage LUXOMAT
®
PD4-DIM-C-FC
The detector has
been designed and
developed specifically
for installation in sus-
pended ceilings.
A circular opening
of diameter 68 mm
must first of all be
produced in the
ceiling.
Having connected
up the cables in accordance with regulations, the
detector is inserted into the opening as shown in the
drawing opposite and fixed into position with the
assistance of the spring clip.
68 mm
b
8. Settings by remote control
Unlocking device - Activation of
the programming mode
Resetting when-
open:
Deletes all
values set with
the remote con-
trol, light OFF.
or
Start of the dim process
Luminance set point for
constant light control
50
Lux
to
1500
Lux
1
min
to
30
min
1
min
to
60
min
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
or
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
optional
optional
optional
t < 5 sec.
Light on / off when closed
=> (see page 2, point 12)
Dimming in the closed state
=> (see page 2, point 11)
Test operation in the closed condition to enable
Disable the test mode: press reset
Resetting when closed
The lighting relay is switched off, i.e. opened and the follow-up times reset.
Permanent protection against sabotage
This function blocks the unit permanently (green LED is illuminated). This
operating mode can only be activated during the period of 5 seconds after
pressing the “lock“ button. This status will only permit actuating the function
“Light on/Light off”. The procedure for leaving this mode is as follows:
1. Switch off the current
2. Apply current for 31 - 59 seconds
3. Switch of the current again
4. Apply current
5. Open detector
Dim in the open state
To set a target value, proceed as follows (example workplace):Place one lux
meter flat on the desk. Set the light with the help of remote control IR-PDim
by pressing the buttons „max“ or „min“ for starting the dim process. Wait
until the desired light level is reached.
Confi rmation by the preset value
Light during the initialization
The light is on by default in the initialization time.
On / off with the „Light“ button during Initialization. The final condition is
then active.
Follow-up time orientation light ON / OFF when open
Note:
Also during the orientation phase of the light constant light control is
active: With sufficient brightness is <20% dimmed and turned off the lights if
necessary.
max
50
Lux
1500
Lux
ON
OFF
t < 5 s
9.
Explanation of the remote control button functions
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
Stop of the dim process and
reading
in the current light value as new
luminance set point
Preset/user mode
=> (see page 2, point11)
Follow-up time light
Orientation lighting and its
follow-up time
Orientation lighting ON/OFF
20 % of the nominal light
Fully automatic/semi automatic
mode => (see page 2, point10)
Locking device – Exit programming
mode
Permanent protection against
sabotage
LED fl ashes
The DIP settings are enabled again by
• Adjusting the DIP switches when closed
• Reset with test sun setting at the potentiometers
• Reset when open
Corridor function:
After deactivation by an external push button, the
detector switches off and returns to automatic mode after 5 sec.
Function LEDs OFF:
In the open state and in test mode, the LEDs are
always ON.
!
In the initialization period
During initialization phase/self test cycle
Lights can be set to on or off status during initialization(60 Seconds) by
using INI OFF/ON mode.
max
50
Lux
1500
Lux
ON
OFF
Light
measure-
ment
Light
measurement