background image

7. Option:

8.  Settings by remote control when open

9.  Description of the key functions 

11.  Manual Dimming – Preset / User 

(for IR-PD-DALI functions see page 2)

You can dim manually by pressing the pushbutton for a long 

time (> 2 sec.). When the button is released, the current dim-

ming value is retained. Upon renewed dimming, the dimming 

direction is reversed.

PRESET

 

 the luminance set point is set during start-up operation by 

the installer and remains unchanged. The luminance set-point confi

-

gured through manual dimming is only applied for the time being. 

Caution: 

The constant light regulation is now deactivated! The currently set 

artificial light is retained independent of the ambient/daylight 

brightness! After switching off and then back on, the originally set 

luminance set-point is reset = constant light regulation is activated.

USER

 

– can only be activated via the remote control!

The luminance set-point is changed upon each manual dimming 

and re-adjusted by the user.

The constant light regulation remains activated!

The system switches over when the “Doublelock” push-button is 

open (see remote control functions, page 1). Each time a push-

button is pressed, the current operating mode is indicated:

Red lights for 3 sec.  

= Preset

Green lights for 3 sec.  

= User

10.  Fully / Semi automatic mode 

(for IR-PD-DALI functions see page 2)

The system switches over when the “Light” push-button is

open (see remote control functions, page 1).

Each time a push-button is pressed, the current operating

mode is indicated by the red LED:

Red lights for 3 sec.  

= Fully automatic mode

Green lights for 3 sec.  

= Semi-automatic mode 

Fully automatic operation

In this operating mode, the lighting switches automatically on 

and off for increased comfort, depending on presence and 

brightness.

Semiautomatic operation

In this operating mode, light can only be switched on manually 

by switch/remote control and switched off automatically upon 

time-out if vacant. 
As many retractable switches as required can be wired in paral-

lel on the “S” input(ON/OFF/Dim).
IR-PD-DALI (27 buttons) can also be used to override the sensor 

as well as IR-PD-DALI (32 button). However, IR-PD-DALI (27button) 

can only override the lighting channel and HVAC run-on time 

has to be set on the potentiometer 3. Whereas, IR-PD-DALI (32 

buttons) can override both lighting channel and HVAC channel.

12. Manual Switching 

 

You can switch the lighting on and off manually by pres-

sing the pushbutton for a short time. It will stay on or off 

as long as people are detected plus the configured follow 

up time.

max

50

Lux

1500

Lux

ON

OFF

max

50

Lux

1500

Lux

ON

OFF

max

50

Lux

1500

Lux

ON

OFF

13. Range of Coverage

PD4

24 m

8 m

6,40 m

24 m

360°

2,50 m

2

1

PD2

10 m

6 m

4 m

10 m

360°

2,50 m

2

1

1

2

quer zum Melder gehen 
frontal zum Melder gehen
Unterkriechschutz

Walking across
Walking towards
Seated

14. PD2/PD4-M-DALI/DSI – Connections

Wall bracket for remote control 

IR-PD-DALI 

IR-PD-DALI

Unlocking device - Activation of 

the programming mode

Locking device – Exit program-

ming mode

Resetting when 

open: 

Deletes 

all values set 

with the remote 

control, light 

OFF.

Follow-up time light

Orientation lighting on/off

Automatic reading in the 

current light value as new 

luminance set point

Permanent protection against 

sabotage

LED flashes

or

Dimming of the lighting on the 

desired luminance value

Adjusting of the luminance set point
+ / – 

small steps 

+

 / 

 

big steps

1

min

to

30

min

max

50

Lux

1500

Lux

ON

OFF

max

50

Lux

1500

Lux

ON

OFF

Switching between DSI and 

DALI program

or

+

Fully automatic /semi automatic 

mode => (see page 2, point 8)

Preset/user mode 

=> (see page 2, point 9)

max

50

Lux

1500

Lux

ON

OFF

Orientation lighting and its 
follow-up time

to

min

10 

min

max

50

Lux

1500

Lux

ON

OFF

t < 5 sec.

Lock device

Test mode 

Reset to deactivate

Resetting when closed

The lighting relay is switched off, i.e. opened and the 

follow-up times reset.

Permanent protection against sabotage  

This function blocks the unit permanently (green LED is illumi-

nated). This operating mode can only be activated during the 

period of 5 seconds after pressing the “lock“ button. This status 

will only permit actuating the function “Light on/Light off”.
The procedure for leaving this mode is as follows:
 

1. Switch off the current 

 

2. Apply current for 31 – 59 seconds  

 

3. Switch of the current again 

 

4. Apply current 

 

5. Open detector

Light on/off when closed 

=> (see page 2, point 10)  

The light will remain switched on/off for as long as movements 

are detected in the areas of coverage. Once the last movement 

has been detected, the light will remain on for the duration of 

the follow-up time as per setting.  

The appliance will then return independently to the mode 

selected (Fully or Semi-automatic).

max

50

Lux

1500

Lux

ON

OFF

t < 5 sec.

L

N

L

N

R

R

Slave

Slave

L L

L

S

S

N N

N

+

+

R

R

T1

T1

DA +
DA –

DA +
DA –

PD2/PD4-M-DALI/DSI-SM

PD2/PD4-M-DALI/DSI-FC

DSI/

DALI

Reviews: