22. PD4-M-2C-SM – Connections
20. Wiring diagram
M
A
N 6
91
5
– 3
10
713
–4
Standard operation Master/Slave
M1 = HVAC function
Optional
T1 = NO-button for semi automatic mode;
Extension of the detection area with Slave-devices
22. LED function displays
PD4-M-2C new
M = HKL Funktion
optional
T1 = NO Taster für Halbautomatikbetrieb
Slave zur Erweiterung des Erfassungsbereichs
Master
Slave
Übersicht
L
N
NO
L´
L
N
C1
N L
R
S
NO
C2
T1
E1
M1
R
22. PD4-M-2C-FC – Connections
22. PD4-M-2C-FM – Connections
LED function indicators after each mains recovery (60 sec. initialisation period)
Operating state
LED function indicators
Factory program
active
White, red and green flash in quick succession for 10 sec., then initialisation indicators,
see below
Double-locked
white and green shines for 5 sec. all 20 sec., afterwards initialising notification
Indicator
unprogrammed
Indicator
programmed
Indicator also when forced shutdown
is activated
Standard mode
Red flashes
Red flashes quickly
Every 5 sec., 4 x white, red and green
in quick succession
12 h ON/OFF
active
Red and green
flash
Red and green flash
quickly
Every 5 sec., 4 x white, red and green
in quick succession
Corridor active
Red and white
flash
Red and white flash
quickly
Every 5 sec., 4 x white, red and green
in quick succession
12 h ON/OFF &
corridor active
Red, green and
white flash
Red, green and white flash
quickly
Every 5 sec., 4 x white, red and green
in quick succession
CdS active
–
Red and white flash
Then no red LED for motion detection
LED function indicators during operation
Process
LED function indicators
Motion detection
Red flashes on each detected movement
Semi-automatic mode
active
White is ON
Impulse active
Red and green flash one time all 4 sec.
Corridor active
White ON 1 sec. and OFF 4 sec.
Corridor and
semi-automatic mode
active
White ON 4 sec. and OFF 1 sec.
Too bright detected
Green flashes
Light measurement
active
Green flashes once every 10 sec.
12 h ON/OFF func-
tion active
Red and green flash alternately
Duration ON active
(by slave)
Red flashes quickly
IR command
White flashes once
IR command „Open“
and sabotage active
White and green flash once slowly
Sensor and power supply in one case
Power supply:
230 V~ ±10 %
Power consumption:
< 1W
Ambient temperature:
-25°C to +50°C
Degree of protection /class:
IP20 / II
Settings:
Potentiometer, DIP-switch
and by remote control
Light values:
20 - 1000 Lux (with remote control)
10 - 2000 Lux (with potentiometer)
Extension of the detection area:
with Slave-devices
Area of coverage:
circular 360°
Range of coverage Ø H 2,50 m / T = 18°C:
seated 6.40 m / tangential 24 m / radial 8 m
Recommended height for mounting:
2 - 3 m
Light measurement:
mixed light, da artificial light
• Channel 1 for light control
Type of contact:
NOC/with pretravel tungsten contact
Contact load:
2300 W cos
ϕ
=1 / 1150 VA
cos
ϕ
= 0.5, µ-Contact
Time-settings:
5 sec. - 16 min./ test with potentiometer
5 min. - 30 min./ test with remote control
• Channel 2 for control devices
(only reacts on motion)
Contact load:
230 V~, 3 A cos
ϕ
=1
Time-settings:
5 min. - 120 min. with time delay of
5 min. for follow-up time > 15 min./ Alarm impulse
Dimensions H x Ø [mm]:
PD4-M-2C SM FC FM
76 x 101 97 x 103 84 x 97
Visible portion when built into ceiling FC:
34 x 10 mm
Technical data PD4-Slave
Power supply:
230 V~ ±10 %
Impulse output:
Optocoupler max. 2 W
Impulse duration:
2 sec. or 9 sec.
Dimensions:
see above
Declaration of Conformity:
The product complies
with the low voltage recommendation 2006/95/EC
and the EMV recommendation 2004/108/EC.
19. Technical data PD4-Master-2C
Wiring diagram
PD4-M-2C-SM
Wiring diagram
PD4-M-2C-FC
Wiring diagram
PD4-M-2C-FM
L
N
R
Slave
L'
L
NO NO
S
N N
R
T1
M1
E1
L
N
R
Slave
L'
L
NO NO
S
N
R
T1
M1
E1
L
N
R
Slave
L'
L
NO NO
S
N
R
T1
M1
E1