Installation and Operating Instruction for
B.E.G.
- Occupancy detector PD4-M-2C-SM/-FC/-FM
LUXOMAT
®
PD4-M-2C/PD4-S
GB
2a. Installation LUXOMAT
®
PD4-M-2C-SM
3a. Hardware configuration SM
Position LED’s and potentiometers
4a. Position potentiometers DIP-Switch SM
5. DIP-switch functions
DIP-
switch
ON
OFF
1
Semi automatic mode
Fully automatic mode
2
LED OFF
LED ON
3
Corridor mode
Standard mode
DIP
OFF
ON
1
2
3
A circular opening of
diameter 68 mm must first
of all be produced in the
ceiling.
Having connected up the
cables in accordance with
regulations, the detector is
inserted into the opening
as shown in the drawing
opposite and fixed into
position with the assistance
of the spring clip.
2b. Installation LUXOMAT
®
PD4-M-2C-FC
The detector can be installed
in conventional inlet-sockets
mounted on the ceiling. The as-
sembly plate enclosed must be
stripped off prior to installation
and secured to the ceiling using
4 screws.
Having connected up the
cables in accordance with
regulations, the detector can be
placed in position as shown in
the drawing opposite and, ap-
plying a little pressure, can then
be locked into position with the
assistance of the spring clips.
( For connections please see
pt. 22!)
2c. Installation LUXOMAT
®
PD4-M-2C-FM
B.I.T
.
Q.C
.
PA
SSED
1
LED 1 green
LED 2 white
LED 3 red
3b. Hardware configuration FC
Position LED’s and potentiometers
Potentiometer 1 Lux Channel1
Potentiometer 2 Time Channel1
Potentiometer 3 Time Channel2
LED 1 green
LED 2 white
LED 3 red
3c. Hardware configuration FM
Position LED’s and potentiometers
Potentiometer 1 Lux Channel1
Potentiometer 2 Time Channel1
Potentiometer 3 Time Channel2
DIP 1
Fully automatic/semi automatic mode
DIP 2
LED ON/OFF
DIP 3
Change between corridor mode and standard mode
The DIP switch settings are overriden using the remote control.
4b. Position DIP-Switch FC
S
L
L
R
Rel2
N
Rel1
230
VAC ±10%
50-60
Hz
False ceiling mounting
ON
OFF
DIP
1
2
3
DIP 1
Fully automatic/semi automatic mode
DIP 2
LED ON/OFF
DIP 3
Change between corridor mode and standard mode
The DIP switch settings are overriden using the remote control.
4c. Position DIP-Switch FM
S
L
L
R
Rel2
N
Rel1
230
VAC ±10%
50-60
Hz
Flush mounting
ON
OFF
DIP
1
2
3
Corridor function:
After deactivation by an external push
button, the detector switches off and returns to automatic
mode after 5 sec.
The DIP settings are enabled again by:
• Adjusting the DIP switches when closed
• Reset with test sun setting at the potentiometers
• Reset when open
closed
open
1. Mounting preparation
Work on the 230 V mains supply
may only be carried out by quali-
fied professionals or by instructed
persons under the direction and
supervision of qualified skilled
electrical personnel in accordance
with electrical regulations.
Disconnect supply before installing!
The device is not suited for safe
disconnection of the mains supply.
When in Master/Slave mode of
operation, the Master-appliance must
always be installed at the location
where there is least daylight.
The detector must be installed
on a solid and level surface.
The circular cover ring
must be removed prior to
assembly. To do this, twist the
lens anticlockwise through ap-
proximately 5° and lift off.
Having connected up the
wires in accordance with
regulations, secure the
detector with 2 screws. After
installation replace the lens
and lock (turn clockwise).
Mains to be connected.
LED 1 green
LED 2 red
LED 3 white
Potentiometer 3 Time Channel2
Potentiometer 2 Time Channel1
Potentiometer 1 Lux Channel1
DIP 1
Fully automatic/semi automatic mode
DIP 2
LED ON/OFF
DIP 3
Change between corridor mode and standard mode
The DIP switch settings are overriden using the remote control.
Surface mounting
OFF
ON
VA
LED
HA
COR
ON
OFF
DIP
40
15
30 1 2 5
10
16
TES
T
120
A
5
60
50
40
30
15
x
1
2 3
1 2 3
1
2 3
1 2
1
2 3
3
40
15
30 1 2 5
10
16
TES
T
120
A
5
60
50
40
30
15
x
40
15
30
1
2 5
10
16
TES
T
120
A
5
60
50
40
30
15
x
1 2 3