Cleaners For Fittings and Accessoires
To avoid
damaging the surface and working components of the fittings, certain precautions must be taken in
terms of usage and subsequent cleaning as many cleaning agents contain acids for general cleaning and
removing calcium deposits. When caring for your fittings a
nd accessories, please note the following:
•
Only apply cleaners which are expressly intended for the use.
•
Never use any cleaner containing hydrochloric acid, formic acid or acetic acid on or near the
fitting, as they can cause considerable damage.
•
Do not use cleaners containing phosphoric acid.
•
Do not use cleaners containing chlorine bleach solutions.
•
Never mix or combine cleaning agents.
•
Abrasive cleaners and unsuitable scouring agents such as scouring pads.
MAINTENANCE
Remove the grub screw (1) using the 1.5 mm wrench supplied. Remove the cap (2). Unscrew th escrew (3)
with a 2.5 mm wrench. Remove the handle (4) and latch ring temperature (5) and the command handle for
opening and closing the water (6). With a 36 mm wrench unscrew the locking ring (7). Replace the cartridge
(8). Assemble in reverse order making sure that the pins at the base of the cartridge (8) are correctly in place
wcich corresponds to the concealed valve and that the surface is clean (fig.9). Reopen the input of water and
verify that the thermostatic mixer functions correctly.