8. 

Connecting the Saddle Valve (diagram 8)

(a) 

Locate Compression Nut in installation kit pack-

age and attach to inlet fitting. Tighten the nut  hand 
tight and then loosen one full turn.

(B) 

Repeat steps 6B and 6C.

9. 

Connecting Inlet Line to System (diagram 9)

(a) 

Locate Compression Nut in installation kit pack-

age and attach to inlet fitting. Tighten the nut hand 
tight and then loosen one full turn.

(B) 

Repeat steps 6B and 6C.

10. 

Setting the Effective Life Indicator

The Effective Life Indicator is the black dial located 
on the center of the mounting bracket. Each white 
mark on the dial represents 378.5L (100 gallons). 
The START mark represents 4542.5L (1,200 gal-
lons); however, the filter cartridges have an effective 
life of 3785.4L (1,000 gallons), so you will need to 
move the dial clockwise so that the indicator arrow 
lines up with the 3785.4L (1,000 gallons) mark  
(2 marks past The START mark). 

important – set  

Effective Life Indicator to 1000 gallons after 
each new filter replacement.

note: To prevent indicator malfunctions, only 
move the dial when the system is depressurized. 

11. 

Putting the System into Operation

(a) 

Slowly turn on cold water supply.

(B) 

Press red pressure-relief button on top 

of system.

c) 

Make sure Effective Life Indicator is set at 

3785.4L (1,000 gallons).

(D) 

Rotate base of drinking water faucet count-

er-clockwise to “ON” position. Allow water to run 
for 5 minutes to flush air and carbon fines from filter 
cartridges. Check system for leaks before leaving 
installation.
note: A drinking water cartridge may contain car-
bon fines (very fine black powder). After installation, 
flush the cartridge for 5 minutes to remove the fines 
before using the water. It is recommended that you 
run the tap at least 20 seconds prior to using water 
for drinking or cooking purposes. 

9333

 

Nanotechnology Under Counter Water Purification System  

 6

Hel neu st 57

Summary of Contents for 9333

Page 1: ...ruction manual For systems filters service t 952 884 8417 e info bdavidwater com w bdavidwater com B David Company World Health Through Water Purification Systems 9333 Nanotechnology Under Counter Water Purification System Hel neu st 57 Rev 12 01 2015 ...

Page 2: ...94 mm x 133 mm x 356 mm 15 5 in x 5 25 in x 14 in Weight filled with water 8 6 kg 19 lbs For systems filters service t 952 884 8417 e info bdavidwater com w bdavidwater com B David Company World Health Through Water Purification Systems 9333 Nanotechnology Under Counter Water Purification System Hel neu st 57 Important Set Effective Life Indicator to 1000 Gallons RS 90 RC 93 RP 100 B David Specifi...

Page 3: ...rly seated in the groove below the threads of the housing or a water leak could occur To prevent costly repairs or possible water damage the sump of plastic housings must be replaced every five years for clear and ten years for opaque If sump is older than recommended replace immediately Date sump for reference and indicate replacement date NOTE For cold water use only Make certain that installati...

Page 4: ...lance fits into hole E Attach back plate of clamp and tighten bolts evenly and firmly so brackets are parallel F Turn valve handle clockwise to closed position and leave closed until installation is complete 2 Selecting the Faucet Location diagram 2 NOTE The drinking water faucet should be posi tioned with function convenience and appear ance in mind An adequate flat area is required to allow fauc...

Page 5: ...4 inch drill bit or hole saw drill a hole completely through the sink Smooth rough edges with a file 3 Mounting the Faucet A Remove wing nut C and metal washer B from the threaded shaft of the faucet Leave the black rubber washer A on the threaded shaft B Slide the threaded shaft of the faucet into drilled hole C From under the sink slide the metal washer on and thread on the wing nut Tighten wing...

Page 6: ... NOTE A squeaking sound when tightening the nut is normal If fittings are removed Teflon tape must be used for pipe threaded connections NOTE Compression nut should come preassembled with ferrules inside If nut should come apart see figure 5A for proper reassembly D Determine the length of tubing needed from the fau cet to the ELI and cut the tubing A slight sag in the lines will allow for some ea...

Page 7: ...with the 3785 4L 1 000 gallons mark 2 marks past The START mark Important set Effective Life Indicator to 1000 gallons after each new filter replacement NOTE To prevent indicator malfunctions only move the dial when the system is depressurized 11 Putting the System into Operation A Slowly turn on cold water supply B Press red pressure relief button on top of system C Make sure Effective Life Indic...

Page 8: ...housing seal Make certain each O ring is seated level in its groove or a leak may occur 5 Screw bottom of housings with bleach water onto caps without filter cartridges and hand tight en DO NOT OVER TIGHTEN 6 Turn on water supply Let faucet run for about 10 seconds then turn off faucet and let stand for 20 30 minutes 7 Turn on faucet and allow bleach water to run out about 3 5 minutes 9333 Nanotec...

Page 9: ...ger This warranty does not cover 1 cartridges and accessories 2 defects not reported within the above time period 3 items manufactured by other companies 4 problems arising from fail ure to comply with B David instructions 5 problems and or damage arising from acts of nature abuse misuse negligence or accident by any party other than B David 6 problems and or damage resulting in whole or in part f...

Page 10: ... n c e Hel neu st 57 Date Activity Service Performed Installation Date B David Company World Health Through Water Purification Systems Tel 952 884 8417 Email info bdavidwater com Visit our website www bdavidwater com ...

Reviews: