B+B A307 Instruction Manual Download Page 3

INSTRUCTION MANUAL

Technical changes reserved  
B+B 0141 0315-02 September 2011

Technical data

Digital thermometer A307

  

Temperature Scale

Celsius or Fahrenheit user-selectable

Measuring range

-50…+1300 °C (-58...+2000 °F)

Resolution

1 °C or 1 °F, 0,1 °C er 0,1 °F

Accuracy

 Accuracy is specified for operating temperatures over the range of 18 

°C to 28 °C (64 to 82 °F), for 1 year, not inclusing thermocouple error
±(0,3% rdg +1°C)       -50…+1000 °C 
±(035% rdg +1 °C) +1000…+1300 °C
±(03% rdg +2 °F) -58…+2000 °F

Input protection

60 V DC or 24 V rms AC maximum input voltage on any combination 

of input pins

Reading rate 

2,5 times per second

Input connector

Accepts standart miniature thermocouple connectors (flat blades 

spaced 7.9 mm, center to center)

Ambient operating range

0…+50 °C (+32...+122 °F)

Storage temperature

-20…+60 °C (-4...+140 °F)

Relative humidity

0...80%    (0…35 °C) (32...95 °F)
0…70%     (35…50 °C) (95...122 °F)

Display

3½-digit liquid crystal display (LCD) with maximum readiung of 1999 

Battery

Standart 9V battery (NEDA 1604, IEC 6F22)

Battery life

200 hours typical with carbon zinc battery

Dimensions

147 mm x 70 mm x39 mm (HxWxD)

Weight

7.4 oz (210 g)

Battery replacement

Power is supplied by a 9 volt „transistor“ battery (NEDA 1604, IEC 6F22). The battery-symbol appears on the LCD 

display when replacmenet is needed. To replace the battery, remove the three screws from the back of the thermo-

meter and lift off the front case. Remove the battery from case bottom.

Warning:To avoid possible electrical shock, disconect the thermocouple connectors from the thermometer before 

removing the cover.

B+B Thermo-Technik GmbH | Heinrich-Hertz-Straße 4 | D-78166 Donaueschingen 

Fon +49 771 83160 | Fax +49 771 831650 | [email protected] | bb-sensors.com

3 / 5

Summary of Contents for A307

Page 1: ...changes reserved B B 0141 0315 02 September 2011 Description Digital thermometer A307 B B Thermo Technik GmbH Heinrich Hertz Straße 4 D 78166 Donaueschingen Fon 49 771 83160 Fax 49 771 831650 info bb sensors com bb sensors com 1 5 ...

Page 2: ...id electrical shock do not use this instrument when voltages at the measurement surface exceed 24 V AC or 60 V AC To avoid damage or burns do not make temperature measurements in microwave ovens Caution Repeated sharp flexing can break the thermocouple leads To prolong lead life avoid sharp bends in the leads espe cially near the connector The symbol on the instrument indicates that the operator m...

Page 3: ... 50 C 32 122 F Storage temperature 20 60 C 4 140 F Relative humidity 0 80 0 35 C 32 95 F 0 70 35 50 C 95 122 F Display 3 digit liquid crystal display LCD with maximum readiung of 1999 Battery Standart 9V battery NEDA 1604 IEC 6F22 Battery life 200 hours typical with carbon zinc battery Dimensions 147 mm x 70 mm x39 mm HxWxD Weight 7 4 oz 210 g Battery replacement Power is supplied by a 9 volt tran...

Page 4: ...he thermocouple connector properly and that the leads are not broken HOLD mode Pressing the HOLD key to enter the DataHold mode the D H annunciator is displayed When HOLD mode is selec ted the thermometer held the present readings and stops all further measurements Pressing the HOLD key again cancels HOLD mode causing the thermometer to resume taking measurements MAX mode Pressing the MAX key to e...

Page 5: ...ts to allow for meassurment lag 4 The calibration of the thermometer thermocouple combination is now optimized for measurements near the tempe rature measured in step 2 Resetting the OFFSET Control To return the OFFSET control to their factory setting without having to recalibrate the thermometer perform the following procedure 1 Connect a thermocouple that is in good working order to the input th...

Reviews: