LR77 v2 Libratum
7. Technical Parameters
7.1
Basic parameters
LR77 v2 Libratum
Temperature range
∗
Function
Storage
-40
◦
C to +70
◦
C
-40
◦
C to +85
◦
C
Humidity
Operating
Storage
0 to 95 % relative humidity non condensing
0 to 95 % relative humidity non condensing
Altitude
Operating
2000 m / 70 kPa
Degree of protection
IP30
Supply voltage
9 to 36 V DC
Battery for RTC
CR1225
Consumption
Idle
GPRS
LTE
2.3 W
to 3.5 W (GPRS transmission)
to 5.5 W (LTE transmission)
Dimensions
Plastic box
Metal box
51 x 87 x 116 mm (DIN 35 mm)
42 x 87 x 113 mm (DIN 35 mm)
Weight
LR77 v2 Libratum – 150 g
LR77 v2 Libratum SL – 280 g
Antenna connector
2x SMA – 50 Ohm
1x R-SMA – 50 Ohm (
only for WiFi
)
User interface
ETH0
ETH1
Ethernet (10/100 Mbps)
Ethernet (10/100 Mbps)
Table 13: Basic parameters
∗
If the router is equipped with WIFI module, the temp. range is reduced to -15
◦
C to +65
◦
C.
7.2
Standards and regulations
The router complies with the following standards and regulations.
Standards and regulations
Telecom and emission
ETSI EN 301 511 V12.5.1 (2017-03), ETSI EN 300 440 V2.1.1
(2017-03), ETSI EN 301 908-1 V11.1.1 (2016-07), ETSI EN 301
908-2 V11.1.1 (2016-07), ETSI EN 301 908-13 V11.1.1 (2016-
07), ETSI EN 300 328 V2.1.1 (2016-11)
Continued on the next page
23