B-52 AT-212 Instruction Manual Download Page 2

2

INSIDE THIS INSTRUCTION MANUAL

Important Safety Instructions / Features.....2

Product Information.......................................3

AT-212 Controls..............................................4-5

Set-up & Warranty Information .....................5-7

Contact Information .......................................8

CAUTION

CAUTION

RISK OF ELE

CTRIC SHOCK

DO NOT OPEN

HEED ALL WARNINGS!

WARNING:

To reduce the risk or fire or

electrical shock do not expose this

equipment to rain or moisture. 

1) Read these instructions.

2) Follow all instructions.

3) Keep these instructions.

4) Heed all warnings.

5)

DO NOT

turn on the AT-212 without the

loudspeaker connected.

6) Do not use the AT-212 near water. Be extra 

cautious when moving the AT-212 during

rain or while transporting it over wet surfaces

as water might splash onto the amplifier.

6)  Clean only with dry cloth.

7)  Do not block any ventilation openings and

operate in accordance with manufacturer’s

instructions.

8) Do not install near heat sources such as 

radiators, stoves or other devices that may

produce heat.

9) Do not defeat the safety purpose of the

polarization or grounding-type plug. A

polarized plug has two blades with one wider

than the other. A grounding-type plug has two

blades and a third grounding prong. The wide

blade or the third prong is provided for your

safety. If the provided plug does not fit your

outlet, consult an electrician for replacement 

of the obsolete outlet.

10)  Protect the power cord from being walked on

or pinched, particularly at the plug and the 

point where it exits the AT-212 amplifier.

11)  Only use attachments / accessories specified

by B-52 Professional.

12) Unplug the AT-212 during lightning storms

and when not in use.

13) Refer all servicing to qualified personnel.

Servicing is required when the AT-212 has 

been damaged in any way such as when

power-cord or plug is damaged, liquid has

been spilled into the amplifier, the unit has

been exposed to moisture or rain, does not

operate normally, or has been dropped. 

14)  To reduce the risk of fire or electric shock, do 

not expose the AT-212 to rain or moisture.

15)  Moisture can damage the AT-212 and can

cause corrosion of electrical contacts.

16) Keep the unit out of extended or intense 

direct sun light.  No containers filled with any 

type of liquid should be placed on or near the 

AT-212.

17)

Never remove the front or rear panels of

the AT-212 while it is connected to an

electrical outlet.

IMPORTANT SAFETY 

INSTRUCTIONS!

This AT-212 is a 3-channel, all-tube, tri-mode rectified combo

that gives you unparalleled tone and astounding versatility.

The clean channel yields sparkling vintage tone that stays

clean even at high volume. The overdrive section features 2

independent high-gain channels and independent volume

controls with a shared 3-band EQ.  The assignable contour

(mid-scoop) control gives you the ability to make each over-

drive channel sound radically different. The Global section

features Low-Res (Resonance), Reverb and Master Volume. 

l

All-Tube Signal Path

l

Tri-Mode Rectifier: Tube - Class A or AB,

Solid-State - Class AB

l

Overdrive Channel: Gain 1 and Gain 2

Each with Independent Master Volumes, 

3-Band EQ, Assignable Contour Control

l

Clean Channel: Master Volume, 3-Band

EQ and Bright Switch

l

Global Controls: Volume, Low-Res

(Resonance) and Reverb

l

Effects Loop with Level Controls (Footswitchable)

l

Line Out with Level Control

l

Selectable 4 / 8 / 16 Ohms External Speaker Jacks

l

4-Position Footswitch: Channel, Gain,

Reverb and Effects Loop

l

Ground Lift Switch

l

Rugged 18mm Baltic birch construction

l

Detachable casters for easy transport

l

Dimenisons: 27” (W) x 11” (D) x 21” (H)

l

Weight: 80lbs.

AT-212 ALL-TUBE COMBO

 

Summary of Contents for AT-212

Page 1: ......

Page 2: ...en damaged in any way such as when power cord or plug is damaged liquid has been spilled into the amplifier the unit has been exposed to moisture or rain does not operate normally or has been dropped 14 To reduce the risk of fire or electric shock do not expose the AT 212 to rain or moisture 15 Moisture can damage the AT 212 and can cause corrosion of electrical contacts 16 Keep the unit out of ex...

Page 3: ...ed pinched or otherwise abused Ensure the power cord is routed to avoid foot traffic Your AT 212 amplifier should be cleaned only with a dry cloth AT 212 100 WATT ALL TUBE 2x12 COMBO THANK YOU FOR CHOOSING THE B 52 PROFESSIONAL AT 212 COMBO The B 52 AT 212 is a feature laden all tube 2 x 12 open backed combo with 100 relentless watts ripping through two custom built B 52 loudspeakers The AT 212 s ...

Page 4: ...s between the clean and overdrive channels Activated LED lights indicate which channel is in use 14 CLEAN CHANNEL BASS Adjusts the amount of low frequency boost or cut as desired Adding bass will increase the depth and fullness of your sound 15 CLEAN CHANNEL MIDDLE Adjusts the amount of mid range 26 AC INLET PRIMARY FUSE Connects AC powercord and houses primary fuse Always use correct value as ind...

Page 5: ...all the way to the left you will experience clean sounds A setting all the way to the right will produce moderate levels of distortion 19 MASTER VOLUME Controls the overall signal level of the AT 212 To increase the overall signal and or volume rotate the control clockwise The Master volume control allows you to preset the output levels of both the Clean and Overdrive Channels 20 MASTER LOW RESONA...

Page 6: ...above GUITAR AMPLIFIER TUBES E T I Sound Systems Inc warrants the orig inal purchaser that amplifier tubes used in B 52 Stealth Series All Tube Amplifiers will be free from defects in material and workmanship for a period of 90 DAYS from the original date of purchase effective January 1 2002 A dated sales receipt will establish coverage under this warranty This warran ty will automatically termina...

Page 7: ......

Reviews: