Copyright © Azoteq (Pty) Ltd 2022
AZBAT24100C User Manual
Page 7 of 13
All Rights Reserved.
Revision 1.02
September 2022
Azoteq
PowerSense
®
Series
Figure 2: AZBAT24100C front panel interface
Table 2 describes the front panel functional interface.
Table 2: AZBAT24100C Interface description
Index
Interface
Description
1
Negative battery
terminals
The battery has a single positive M8 terminal with a terminal cover for
external connections.
2
LCD Display
Displays the battery voltage and estimated State of Charge based on
the battery voltage with no load. Please refer to the Estimated SoC vs
Voltage sticker on the front of the battery to validate the state of
charge.
3
LCD Display Button
Switches power to the LCD display ON and OFF.
Note that this does not power down the battery terminals.
4
Positive battery
terminals
The battery has a single positive M8 terminal with a terminal cover for
external connections.
5
Specification Sticker
Battery specifications and limitations
6
Handle
Spring loaded aluminum handles for improved handling and transport.
Installation
Please read the installation manual of the inverter in conjunction with this installation manual. All
wiring, cable sizing and installation requirements must be in regulation with the specified installation
requirements as governed by the relevant authority in the country of installation. Please ensure that
a qualified installer familiar with the installation requirements is used for the installation.
The installation details must be sent to Azoteq for the warranty to apply along with an electrical
Certificate of Compliance (CoC). Please download and complete the warranty document from the
Azoteq website (
https://www.azoteq.com/warranty/)
Hardware required
The following items are required to install the battery. Please note these items are
not
included with
the battery.
1. Positive (red) and Negative (black) power cables with M8 lugs on the battery side and as per
requirements on the inverter side.
a. Recommended cable thickness:
i.
≥35mm
2
for 3-5kW installations
ii.
≥50mm
2
for 8kW installations
2. DC overcurrent protection (fuse) and isolator for additional protection and compliance.
3. It is recommended to install the batteries in a cool and dry environment.
a. It is not recommended to place the batteries directly on the ground.
b. Do not operate the batteries in areas with temperatures outside the range of 0°C to
45°C