Azbil Corporation
Instrument installation
Model MCB10A 2-9
Tightening torque
CAUTION
Table 2-1 shows the tightening torques by bore diameters. To prevent leakage from
the pipe, use the centering fixtures and fix with the prescribed tightening torque. A
leakage would bring about the danger of injury.
Table 2-1 Tightening torque
Nominal bore diameter of sensor
Tightening torque
15 mm
13 - 18 N•m (130 - 180 kgf•cm)*
25 mm
20 - 30 N•m (200 - 300 kgf•cm)*
40 mm, 50 mm, 65 mm, 80 mm
30 - 50 N•m (300 - 500 kgf•cm)*
100 mm
50 - 70 N•m (500 - 700 kgf•cm)*
*:
Values in parentheses are for information only.
Flange shape
Referring to Figure 2-7, use a flange that gives a large area of contact with the gasket.
Good example
Bad example
Flange
Weld
Weld
Pipe
(Because the area
of contact with the
gaskets is small,
there is a risk of
leakage)
Figure 2-7 Flange shape
~Note
•
Prior to installing the detector, always do flushing (washing of
pipe) to remove foreign matter inside the pipe. Otherwise, output
fluctuations may result.
•
Do not touch the electrodes with your hand, an oily rag or the like.
Otherwise, output fluctuations may result.
•
Make the flow direction mark of the detector agree with the direction
of the fluid flow. In case of disagreement, no output will be delivered.