AB-6758
6
Assembling the Valve with the Actuator Model MY5302C
IMPORTANT:
Do not use any other actuator than those specially made for this valve.
The actuator can be horizontally rotated every 90 degrees to fit into the valve mounting position. Refer to
Figure 5 and make sure that the actuator and the vale look as shown (fully open position) before shipping.
- Actuator: Indicator/manual lever points at 100.
- Valve:
An arrow on the top of the stem points at 100.
Align the hole on the side of the stem should be aligned with the tip at the joint surface.
(See “a” in Figure 5)
Set both the actuator and the valve in 100 % position (full open) when changing the mounting position. If the
valve in 0% position is assembled with the actuator in 100 % position, the actuator puts torque on the closed
valve, and the gear of the actuator gets damaged.
Figure 5 Mounting the Actuator onto the Valve
Mounting procedure
(1) Manually turn the indicator/manual lever of the actuator to "100" with the lever release button pressed.
Figure 6 Indicator/Manual Lever at 100% Position (Full Open)
(2) Move the lock lever to the right end as shown in Figure 7.
Figure 7 Lock Lever (Released)
Press
Turn
Turn
Lock lever
Actuator
Model MY53X0A
Valve
Model VY5302C
Press
Stem
a
Lever release
button
Indicator/
manual lever
リリース状態
In a released position