background image

USER MANUAL

 _

 8

If the screen fails to respond, hold the “Mode Esc” key down for at least 3 
seconds to free up the display. 

The fixture’s menu functions are described in the following table:

TABLE 1: VERSAPIX-RS MENU FUNCTIONS AND OPTIONS

Address

Set Dmx Addr

A001~AXXX

DMX address setting

Mode

User Mode

Stand Mode
Basic Mode
Extend Mode
User Mode A
User Mode B
User Mode C

User’s mode to change 
channel numbers

Edit User

Max channel
Strobe
:

Preset User modes

Options

Status

No DMX Mode

Close/Hold/Auto

Auto run if no DMX

Service PIN

Service PIN
RDM PID 

Password=XXX
xxxxxx 

Service Password”=050”
RDM PID Code

Fans Control

Auto
Stage
Studio

Fans Speed select

Disp.Setting

Shutoff Time
Flip Display
Key Lock
DispFlash

02~60m 05m
ON/OFF
ON/OFF
ON/OFF

Display shutoff time
Reverse 180 degree
Key Lock
No Signal Flash

Temp. C/F

Celsius
Fahrenheit

Temperature switch 
between

Initial Pos.

Strobe =XXX

Initial effect position

Trigger

DMX Value Disp.
Set To Slave
Auto Program

Strobe……
Slave1,Slave2,Slave3
Master / Alone

DMX value display
Slave setting
Auto program

ResetDefault

ON/OFF

Restore factory set.

Info

Time Info.

Current Time
Ttl Life Hrs
Last Run Hrs
Timer PIN
Clr Last Run

XXXX(Hours)
XXXX(Hours)
XXXX(Hours)
Password=XXX
ON/OFF

Temp. Info

Head Temp.

XXX °C/°F

Software Ver

V1.0...

Software version

Test

Test Channel

Strobe ……

Test function

Manual Ctrl.

Strobe =XXX
:

Fine adjustment of 
parameters

Preset

Select Prog.

Prog. Part 1 = Program 1 ~ 10  Program 1
Prog. Part 2 = Program 1 ~ 10  Program 2
Prog. Part 3 = Program 1 ~ 10  Program 3

Select programs to be run

Edit Prog.

Program 1
:
Program 10

Program Test
Step 01=SCxxx
Step 64=SCxxx

Testing program 
Program in loop
Save and exit

Edit Scenes

Edit Scene 001
~ Edit Scene 250

Pan,Tilt,……
--Fade Time--
--Secne Time--
Input By Outside

Save and automatically 
return
manual scenes edit

Scenes Input

XX~XX

Automat. scenes rec

VERSAPIX-RS CONTROL PANEL MENU – OPTION 
DETAILS    

The following section provides details on the options that can be selected 
through the control panel menu. Refer to the table above.

Note: You can exit this menu at any time by pressing “Mode Esc” repeatedly 
until you return to the home screen. 

ADDRESS

SET DMX ADDR

Allows you to change a DMX address from the fixture’s control panel.

 

w

 Access the menu by pressing the “Mode Esc” key.

 

w

 Go to the “ADDRESS” menu and press “Enter”, then find “Set DMX 
Address.”

 

w

 Use the up/down arrows to scroll through until you locate the desired 
address and press “Enter” to confirm.

MODE

USER MODE

Allows you to select the DMX mode from the following: “Basic Mode” (6, 
12, 29 DMX channels ), “Standard Mode” (12 DMX channels), “User Mode 
A”, “User Mode B”, “User Mode C.”

 

w

 Access the menu by pressing the “Mode Esc” key.

 

w

 Use the up/down arrow keys to reach the “MODE” menu and press 
“Enter.” Then from “User Mode” choose one of the 6 modes above.  
Consult the “CHART DMX” table for more information on Basic and 
Standard Mode. “User Modes A”, “B”, or “C” are user-definable.

EDIT USER A, B, C

To customize the mode, go to “MODE” and select “Edit UserMode A, B or 
C” and press “Enter.” Scroll through each setting and press “Enter” to set 
the desired address.

OPTIONS

STATUS
No DMX Mode

Defines the fixture’s state when there is no command signal from the DMX 
controller. The fixture can either launch a program automatically, close the 
shutter, or even remain in the state when the last DMX values (Hold) were 
received. The default setting is “Hold.”

 

w

 Access the menu by pressing the “Mode Esc” key.

 

w

 Use the up/down arrow keys to reach the “OPTION” menu and press 
“Enter.” Then use the left/right arrow keys to select “Status.” Finally, use 
the left/right arrow keys to select “No DMX Mode.”

 

w

 Scroll through the different options using the left/right arrows and press 
“Enter” to confirm.

SERVICE PIN

WARNING! For normal operation the “Service pin” menu information 
should not be changed. Contact your dealer for more information. 

Service PIN

Allows you to enter a password to access the advanced options such as 
RDM PID (pwd: 50).

 

w

 Access the menu by pressing the “Mode Esc” key.

 

w

 Use the up/down arrow keys to reach the “OPTION” menu and press 
“Enter.” Finally, use the left/right arrow keys to select “Service Pin.”

 

w

 Scroll up to “50” using the left/right arrows and press “Enter” to confirm.

RDM PID

Allows you to set the fixture’s RDM PID code.

 

w

 Access the menu by pressing the “Mode Esc” key.

 

w

 Use the up/down arrow keys to access the “OPTION” menu and press 
“Enter.” Then use the left/right arrow keys to select “Service Pin.” 

Summary of Contents for VersaPix-RS

Page 1: ...USER MANUAL V 1 1 ENGLISH VERSION 21 06 2016...

Page 2: ......

Page 3: ...n and features Dimensions Description Installation instructions DMX512 connection Control Panel VersaPix RS control panel menu Option details Master Slave Mode settings DMX Chart Error Messages Care a...

Page 4: ...wer cables attached to your VERSAPIX RS have not been damaged due to cuts and splices or crushed in any way Handle these cables with extreme caution while they are connected to a power source Your VER...

Page 5: ...glass that fall on the unit may cause breakage of the plastic parts or the body AYRTON cannot be held responsible for the luminaire s broken plastic parts or body which are not covered under warranty...

Page 6: ...mantled or serviced The operator must ensure that a qualified technician has approved the installation of the luminaire for safety before it is first operated Installation should be inspected once a y...

Page 7: ...rol information sent by the DMX controller The start address must conform to the one recorded on the DMX controller to run the luminaire This address is the DMX value that appears on the luminaire s d...

Page 8: ...home screen ADDRESS SET DMX ADDR Allows you to change a DMX address from the fixture s control panel w w Access the menu by pressing the Mode Esc key w w Go to the ADDRESS menu and press Enter then f...

Page 9: ...enu by pressing the Mode Esc key w w Use the up down arrow keys to reach the OPTION menu and press Enter Then use the left right arrow keys to access the Temp C F submenu w w Use the left right arrow...

Page 10: ...ion of the fixture w w Access the menu by pressing the Mode Esc key w w Use the up down arrow keys to reach the INFO menu and press Enter Then use the left right arrow keys to access the Software ver...

Page 11: ...u Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Program Part 1 is Program 2 Auto Program Part 2 is Program 3 Auto Program Pa...

Page 12: ...Mode Channel Value Function St Ba Ex 10 6 Chase Patterns 0 15 Led trun off 16 31 Chase 1 32 47 Chase 2 48 63 Chase 3 64 79 Chase 4 80 95 Chase 5 96 111 Chase 6 112 127 Chase 7 128 143 Chase 8 144 159...

Page 13: ...istorted in any way or show any trace of corrosion The safety cable should be attached at the appropriate spot Mechanical parts should show no sign of wear The electrical cables should show no sign of...

Page 14: ...iagram A A 750 325 220 R 3 0 WARRANTY The AYRTON VERSAPIX RS fixture is guaranteed against manufacturing defects for the duration of one 1 year from the date of purchase This warranty does not cover t...

Page 15: ...USER MANUAL _ 15...

Page 16: ...www ayrton eu...

Reviews: