19
Installation and disassembly of heat discharge pipe
Note of Install heat discharge pipe
In order to improve cooling efficiency, the heat discharge pipe should be as
short as possible and flat without curve to ensure smooth heat discharge.
correct
correct
correct
wrong
● The length of the exhaust pipe is less than 1m. It is recommended to use it with
shortest length.
● When installing, exhaust pipe should be as flat as possible. Don't prolong the
pipe or connect it with other exhaust pipe.