background image

Should the AC line voltage drop below 80% of normal
(brown-out), the unit will revert to “Warm-Up” mode and
the indicator light will glow red. After the voltage returns
to normal, the initial warm-up cycle will begin again.

The Ayre V-1x also incorporates a sensor to detect the
presence of DC at the output terminals. In this case, the
amplifier reverts to “Warm-Up” mode, the indicator light
glows red, and power is immediately removed from the
output stage. If the fault is still present when the front
panel switch is pressed to “Operate” after the warm-up cycle
is completed, the unit will immediately revert to the
“Warm-Up” mode again.

Remote Control

The remote control included with the Ayre V-1x has four
buttons. The single button on the left side of the hand-held
transmitter will select the “Standby” and “Operate” modes
on the amplifier, duplicating the action of the front-panel
switch. The three buttons on the right side of the remote
control will operate an Ayre preamplifier.

Break-In

100 to 500 hours of music

played through the system will

assure full break-in.

Due to the manufacturing processes used for the wires and
capacitors, a break-in period is necessary for the amplifier to
reach its full sonic potential.

Page 6

Summary of Contents for V-1x

Page 1: ...A y r e V 1x Power Amplifier Owner s Manual...

Page 2: ......

Page 3: ...Table of Contents Welcome to Ayre 2 Installation and Operation 3 In Case of Trouble 7 Numbers and Specifications 8 Statement of Warranty 9 A Place for Notes 11...

Page 4: ...The warmth and immediacy of a live performance are apparent from the first listening The combination of superb resolution and a natural relaxed quality will draw you into the music time and time again...

Page 5: ...ly of air flow to avoid overheating the amplifier Good locations for your amplifier are on the floor or in an open backed cabinet or rack If the amplifier is placed in a cabinet be sure to provide at...

Page 6: ...situation Selecting Unbal connects the inverting input to ground through an isolation resistor Therefore the incorrect setting of this switch forces a balanced source to operate in unbalanced mode Con...

Page 7: ...nt panel switch is inoperable The remote control can also be used to select the Standby and Operate modes After the circuitry has stabilized the indicator light will change to green indicating that th...

Page 8: ...pressed to Operate after the warm up cycle is completed the unit will immediately revert to the Warm Up mode again Remote Control The remote control included with the Ayre V 1x has four buttons The s...

Page 9: ...x are in place Also be sure that the amplifier is connected to a working AC outlet Is the AC circuit breaker OK The power switch on the rear of the unit incorporates an AC circuit breaker In the case...

Page 10: ...inuous into 8 ohms 400 watts per channel continuous into 4 ohms Gain 26 dB Input Impedance 100 k per phase Power Consumption 30 watts in standby mode 300 watts in operating mode no signal Dimensions 1...

Page 11: ...oustics Inc Ayre warrants the materials and workmanship of this product for a period of five years from date of first purchase If any defects are found in the materials or workmanship of this Ayre pro...

Page 12: ...merchantability or fitness for any particular purpose shall be strictly limited in duration to five years from the date of original purchase and upon expiration of the warranty period five years Ayre...

Page 13: ...A Place for Notes Page 11...

Page 14: ...Page 12 Rev 1 1...

Page 15: ......

Page 16: ...Ayre Acoustics Incorporated 2300 B Central Avenue Boulder Colorado 80301 303 442 7300 www ayre com...

Reviews: