Setting up the unit
To activate the unit, connect the appropriate included power cable to the unit and to a suitable 230V, 50Hz
power outlet.
The fixture will start up and show the last chosen setting on the display. For a new product, this is usually the
DMX mode with the value set to 001. During start-up the display reads 'Ayra'. After this, the last used mode
will be shown and the settings and values can be changed.
The display shows several settings, each with the possibility of setting several values.
Use the display and the menu buttons on the bottom to set preferences, change settings and scroll through
the menu. “Enter” is used to save a certain setting or preset, press “Menu” for at least 2 seconds to return to
the main menu.
The table below shows an explanation for every feature and value.
display
Mode
Function
ADDR
DMX address setting
A001-A512
CHND
Channel mode
1CH/3CH1/3CH2/4CH/6CH/7CH/13CH/36CH
SLND
Master/slave mode
Master (default)
Slave 1 - Slave 2
SHn1
Show mode 1
Auto mode – mix colour. Select speed SP0-9
SHn2
Show mode 2
Auto mode – user-selected colour. Select speed
SP0-9 and select colour COL1-7
COLO
Colour preset
Full on – Colour preset 1-7
SOUN
Sound-controlled mode
Sound-controlled mode on/off, overrides
selected speed of SHn1 or SHn2
SENS
Sound sensitivity
Sound sensitivity 0-100
BALA
Colour balance
Select colour balance for red, green, blue (50-
255)
BLND
LED mode
ON-OFF
LED
LED display on/off
Select display on/off during use (when on, will
shut off after several seconds)
DISP
Display inversion
Display Inversion, Idsp-dspI
TEST
Test mode
Self test
CPU
Inner test programs
CPU check
Code B10 + C10 = working OK
Hour
Using time of light
Fixture hours, 0 ~ 9999
Ver
Software version
Only for information
ADDR:
DMX address setting, used to determine the DMX starting channel. From this channel on, the fixture
will respond to values, corresponding with the amount of channels that the fixture is occupying. (For
example, when you set the starting address to value 003, the fixture will respond to channels 3, 4, 5 etc.)
CHND:
The channel mode of the fixture makes it possible to use the correct channel mode setting for every
application. For simple and basic setups, users may prefer to use the 1CH or 3CH mode. For advanced
setups, users may prefer to choose the 36CH mode to be able to control the colour of every pixel.
SLND:
When using the master/slave function, connect 2 or more fixtures with standard 3p XLR male - XLR
female cables. The first fixture in line needs to be set as master, the others as Slave 1 or 2 (synchronised or
mirrored performance in sound-activated mode). This way, the slaves will mimic the behaviour of the master
fixture for amazing synchronised light shows. The default setting of the fixture is master.
SHn1:
Show mode 1, which is the auto colour mix mode. When this mode is selected, the internal programs
of the bar are run in a standard order, with several colour changes and effects. When selecting this mode, the
user also has to select the desired speed, which is set by SP0-9. Press enter to select the value and press
All information and illustrations shown in this user manual are subject to change without further notice.
User manual version: 1.0
Creation date + author initials: 02-02-2015 RV Revision date + author initials: 02-02-2015 RV