13 PROPER USE
Attention! The air compressor may only be used indoors (in the
house) .
Only normal air may be compressed in this compressor. Apart from the
normal ambient air, it is prohibited to compress any other air types, such
as explosive air.
13.1
Improper use
This piston compressor is not suitable for continuous operation or unrestricted
commercial operation and may only be used in dry rooms.
The use in explosive environments as well as pointing the compressed air gun
at persons is prohibited.
13.2
Residual risk
Follow the corresponding maintenance and safety instructions as provided in this
instruction manual. Despite wearing protective equipment (protective goggles), dirt
particles, dust etc. can get into your eyes or face.
Always stay alert when working and keep other persons at a safe distance from your
workplace.
If the compressor and the compressed air line are damaged, contact your dealer for
repair.
If the compressor makes abnormal noises, switch it off immediately and contact a
dealer.
To protect against exposure to noise when operating the air
compressor, always wear corresponding protective equipment
(hearing protection)
.
14
TECHNICAL DATA
MODEL
Nominal voltage
220-240 V~ 50-60 Hz
Input power
300W
Idle speed
4500 rpm
Max. operating pressure
10 bar
Tank
6 litres
Lubrication type
Oil-free
Air flow rate (@ 6 bar)
17 L/min
Protection class
IP20
Weight
7.71 kg
Ambient temperature range
+5 °C -- +40 °C
Humidity
>
50 % (max. temperature: +40 ºC)
Installation altitude
<
1000 m