MAINTENANCE 
 
ATTENTION: 

Make sure that the product is disconnected from the mains line, even if the 

product is turned off during the maintenance and cleaning of the product. 
 

 

Be sure to read the instructions before starting the maintenance and cleaning 
operations. 

 

Do not operate on a running fan. 

 

The maintenance of the product should be done at least once every six months or more 
frequently, depending on the place and frequency of use. The maintenance and cleaning 
of the product should be done by qualified personnel. 

 

If any malfunction is detected in the electrical system during maintenance, the defective 
parts must be replaced. Continuing the operation of the fan without rectifying the 
detected fault may cause great dangers. 

 

Be sure to wear your safety equipment during cleaning and maintenance. (Gloves against 
cuts, etc.) 

 

When fuses or switches are damaged, definitely replace them, do not try to repair them. 

 

Check if there is a change in the vibration level of the product after maintenance. 
Otherwise, contact the manufacturer. 

 

The propeller is subject to natural wear depending on the application and transport 
environment. Deposits on the propeller can cause imbalance and damage. (Permanent 
breakage hazard) If this is the case, do not try to repair the impeller, definitely replace 
the propeller. 

 

During the cleaning of the product, do not contact the product directly with water, do 
not use flammable and combustible cleaners, clean the product with a damp cloth. Make 
sure that no water enters the engine. 

 

If the impeller is disassembled from the product for cleaning, make sure it is mounted 
correctly during installation. 

 

While cleaning the product, be careful to maintain the balance of the impeller. 

 

It should only be changed by AYAS employee in case of damage to the impeller or blade. 
The manufacturer cannot be held responsible for damage caused by improper repair 
work. 

 

The performance of the fan may decrease due to contamination, so periodic 
maintenance and cleaning is required. 

 

Check the condition of the threaded connections when opening the cable glands on the 
motor. 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for BTA Series

Page 1: ...T RLER AX AL FAN CHIMNEY KULLANIM KILAVUZU GARANT BELGES INSTRUCTION MANUAL WARRANTY CERTIFICATE BTA 160 4K M BTA 200 4K M BTA 250 4K M T rk e i in 1 ve 8 numaral sayfa aral incelenmelidir For English...

Page 2: ...k oldu undan emin olunuz r n n duvara veya kanala montaj ndan nce pervanede kasada zgarada hava ak koridorunda kanal nda pervanelere hasar verebilecek g zle g r l r bir kat cisim bulunmad ndan emin ol...

Page 3: ...00 650 48 BTA 250 4K M 220 50 50 0 29 1400 900 49 r n n teknik verileri ilgili standartlara g re laboratuvar artlar nda test edilip onaylanm de erlerdir Bu de erler r n n kullan m ve ortam artlar na g...

Page 4: ...plar n ay r c bir devre kesici d zenekle ba lay n r n zerinde olan etiketlerde g sterildi i gibi hava y n ne uygun monte etti inizden emin olun Fana deneme al mas yap n z r nde titre im ve hata olup o...

Page 5: ...ktrik ba lant lar n n g venli ve elektrik ba lant emas nda g sterildi i gibi oldu undan emin olmadan r n al t rmay n B t n ekipmanlar n uygun ekilde ba lanm oldu undan emin olunuz Topraklama ba lant l...

Page 6: ...esinde bir de i iklik olup olmad n kontrol ediniz Aksi durumda reticiyle ileti ime ge iniz Pervane uygulama alan na ve ta ma ortam na ba l olarak do al a nmaya maruz kal r Pervane zerindeki tortular d...

Page 7: ...kirden ve hava artlar na kar koruyunuz Uzun s reli depolamadan ka n n en fazla iki y l neriyoruz r nler dikkatli bir ekilde s k tutularak ta nmal Savurma elden ele atmalardan ka nmal d r H ZMET YA AM...

Page 8: ...problemleri elektriksel problemleri ile sorunlar i erisinde M teri g kayna ve voltaj kayna sorunlar r n garanti kapsam d ndad r 6 M teri firma personellerinin cihaz hatal kullan m veya m teri i letme...

Page 9: ...Ve Tic Ltd ti MERS S NO S C L NO 108041183800015 ADRES Karayollar Mahallesi 648 Sokak 18 A Gaziosmanpa a stanbul TELEFON 902126127393 E POSTA info ayas com tr F RMA KA E SATICI F RMANIN BAY N N NVANI...

Page 10: ...duct to the wall or duct it should be ensured that there are no visible solid objects in the fan case grill air flow corridor duct that can damage the fans It must be connected to the fixed installati...

Page 11: ...8 BTA 250 4K M 220 50 50 0 29 1400 900 49 The technical data of the product are the values tested and approved under laboratory conditions according to the relevant standards These values may vary acc...

Page 12: ...hown in the figure Make sure you have connected the power cable correctly as in the electrical diagram Connect the device poles with a disconnecting circuit breaker Make sure to install according to t...

Page 13: ...ctricity from the source Do not operate the product without making sure that the electrical connections of the product are safe and as shown in the electrical wiring diagram Make sure all equipment is...

Page 14: ...in the vibration level of the product after maintenance Otherwise contact the manufacturer The propeller is subject to natural wear depending on the application and transport environment Deposits on...

Page 15: ...until installation Avoid long term storage We recommend a maximum of two years Products should be handled carefully and tightly Tossing should avoid hand tosses SERVICE LIFETIME Established service p...

Reviews: