Z.I. Les Bosses
F-26800 ETOILE-SUR-RHONE
www.axxair.com
- 19 -
English
Note: Before performing any operation on the DC115, unplug the motor, so as to
prevent any risk of accident.
4.1 Installing a tool holder (facing and chamfering):
Firstly, unscrewing and remove the protection.
In the case of a facing tool holder
, install the tool holder on the plate, and then adjust
its position according to the tube diameter to be machined (centre the plate on the tube
thickness).
In the case of a chamfering tool holder
, position the tool holder on the plate, then
install the tube to be machined. Position the plate tangentially on the tube (to obtain the
chamfer starting point), then move the chamfering tool holder towards the centre, as a
function of the depth of chamfer required: 1 mm displacement = 1 mm of chamfer depth.
Caution, for chamfering only, the tool at 45° allows a maximum chamfer depth of
5 mm, while the tool at 30° allows a maximum depth of 7 mm.
In order to blunt the outer edge of the tube, the chamfering tool may be used at the
same time as the facing tool (mounted symmetrically).
Finally, lock the tool holder in position by tightening the locking screw (ref. 1), using the
Torx T15 screwdriver supplied (tighten to torque 2.55 Nm).