0 2
EN
A S S E M B L Y (see page 12)
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children as well as adults with physical, mental and/or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The mesh washer must be insert to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or/and can damage parts of the shower;
such caused faults voids all liability and guarantee claims.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
150±12 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
S A F E T Y F U N C T I O N (see page 05)
The desired maximum temperature for example max. 42º C can be pre-set
thanks to the safety function.
A D J U S T M E N T (see page 05)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
M A I N T E N A N C E (see page 12)
⁄ The check valves must be checked regularly according to DIN EN 1717
in accordance with national or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page )
F L O W D I A G R A M (see page 07)
Hand shower
Bath Spout
S P A R E P A R T S (see page 10)
C L E A N I N G (see page 11)
O P E R A T I O N (see page 06)
H O T A N D C O L D S U P P L I E S A R E R E V E R S E D
(see page 12)
F A U L T
C A U S E
R E M E D Y
⁄ Insufficient water
⁄ Supply pressure inadequate
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Regulator filter dirty
⁄ Clean filter in front of the mixer and on the MTC-thermo car-
tridge
⁄ Shower filter seal dirty
⁄ filter insert shower dirty
⁄ Clean filter seal between shower and hose
⁄ Clean filter insert between shower and hose
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Backflow preventers dirty or leaking
⁄ Clean backflow preventers, exchange if necessary
⁄ Spout temperature does not correspond with temperature
set
⁄ Thermostat has not been adjusted
⁄ Adjust thermostat
⁄ Hot water temperature too low
⁄ Increase hot water temperature to 42 ºC to 65 ºC
⁄ Temperature regulation not possible
⁄ thermo cartridge calcified
⁄ Exchange thermo cartridge
⁄ For new installations: basic body incorrectly connected
(should be: cold right, hot left) or installed with 180º rota-
tion
⁄ Install function block turned through 180º (see page 12)
⁄ Safety stop button not operating
⁄ Spring defective
⁄ Button calcified
⁄ Clean spring and/or button, exchange if necessary
⁄ Valve stiff
⁄ Shut-off unit damaged
⁄ Exchange shut-off unit
⁄ Shower or spout dripping
⁄ Dirt or sedimentation on valve seat.
⁄ Clean or exchange shut-off unit
Summary of Contents for Urquiola 11437009