A S S E M B L Y   (see page 24) 

EN

I N S T A L L A T I O N   E X A M P L E   (see 
page 4)
Adjust the module arrangement to the local 
conditions

Do not use silicone containing acetic acid!

S Y M B O L   D E S C R I P T I O N

D I M E N S I O N S   (see page 27)

S A F E T Y   N O T E S

 

Gloves should be worn during installation to prevent crushing and cutting injuries.

 

The product may only be used for bathing, hygienic and body cleaning purposes.

 

Children as well as adults with physical, mental and⁄or sensoric impairments must 
not use this product without proper supervision. Persons under the influence of 
alcohol or drugs are prohibited from using this product.

 

Do not allow the streams of the shower touch sensitive body parts (such as your 
eyes). An adequate distance must be kept between the shower and you.

 

The hot and cold supplies must be of equal pressures.

 

E L E C T R I C A L   C O N N E C T I O N

 

The electrical connection may only be carried out by an electrician!

 

Preinstall electrcal power 230 V⁄N⁄PE ⁄50 Hz (length: 0.3 m)

 

The current version of the applicable regulations from VDE, local authorities and 
utility companies must be observed for electric installation work.

R E S I D U A L   C U R R E N T   P R O T E C T I O N   S Y S T E M

 

The system must be protected via a leakage current protective device  (RCD⁄ FI) 
with a measurement difference current of ≤ 30 mA.

 

E L E C T R I C I A N

 

The installation and testing work must be performed by a skilled electrician in 
observance of VDE 0100 part 701 and IEC 60364-7-701.

I N S T A L L A T I O N   I N S T R U C T I O N S

⁄  Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

⁄  The pipes and the fixture must be installed, flushed and tested as per the applicable 

standards.

⁄  The plumbing codes applicable in the respective countries must be observed.
⁄  During installation of the product by qualified trained personnel, make sure that the 

entire fastening surface is even and smooth (no protruding seams or tile offset), that 
the finish of the wall is suitable to apply the product and has no weak points.

⁄  Observe all current and water lines when drilling!
⁄  The performance of the waste must be of sufficient size.

T E C H N I C A L   D A T A
Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

 

(1 MPa = 10 bar = 147 PSI)

Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

65°C

Connections: 

G1⁄2 & G3⁄4

Rate of flow by 0,3 MPa:
10750187 (1 Consumer) 

44 l⁄min

10750187 (2 Consumer) 

55 l⁄min

10650187 

25 l⁄min

10971187 

55 l⁄min

28486187 

50 l⁄min

Thermal disinfection: 

max. 70°C ⁄ 4 min

The product is exclusively designed for drinking water!
Safety against backflow

S P A R E   P A R T S   (see page 29)

E L E C T R I C I A N

M A I N T E N A N C E
The check valves must be checked regularly 
according to DIN EN 1717 in accordance with 
national or regional regulations (at least once 
a year).

Water connection DN20
Warm water

T R A N S F O R M E R

Water connection DN20
Cold water

C E N T E R   S H O W E R   T U B

T U R N   O N   W A T E R   ⁄   T U R N   O F F 
W A T E R

I L L U M I N A N T

A R E A   F O R   R E Q U I R E D   W A L L   R E -
I N F O R C E M E N T
The wall must be reinforced in this area.

A M P L I F I E R   F O R   S P E A K E R

C O N N E C T O R S

E M P T Y   P I P E   E N 2 0

S A F E T Y   G L O V E S   M U S T   B E 
W O R N

E L E C T R I C I T Y   O N   ⁄   O F F

I N S T A L L A T I O N   S E Q U E N C E

P L U G   O U T L E T S
Plug the unused outlet.

P I P E   D E C L I N E
Install water pipes for body showers with a 
gradient.

P O T E N T I A L   E Q U A L I S A T I O N

N E U T R A L   C O N D U C T O R

C O N D U C T O R

L I G H T   S W I T C H

F I   P R O T E C T I V E   S W I T C H

Summary of Contents for ShowerCollection 10650187

Page 1: ...I N S T A L L A T I O N Z H 02 E N assembly instructions 03 AXOR ShowerCollection 10971187 AXOR ShowerCollection 10750187 AXOR ShowerCollection 10650187 AXOR ShowerCollection 28486187...

Page 2: ...30V N PE 50Hz 0 3 30 mA VDE 0100 701 IEC 60364 7 701 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 70 C 65 C G1 2 G3 4 0 3 MPa 10750187 1 44 10750187 2 55 10650187 25 10971187 55 28486187 50 70 C 4 2...

Page 3: ...led flushed and tested as per the applicable standards The plumbing codes applicable in the respective countries must be observed During installation of the product by qualified trained personnel make...

Page 4: ...10971187 10750187 28486187 10650187 N L PE 40871000 40874000 40872000 28491007 10972007 10751007 28491007 10651007 Showerheaven 970 x 970 10621807 10623807 Showerheaven 720 x 720 10625807 10627807 DN...

Page 5: ...1 2 2 1 3 4 5 4 Laminar 3 Rain 5 Body 5 i...

Page 6: ...20 DN 20 DN 20 DN 20 28486187 4x 10650187 40878180 10971187 10750187 28491007 4x Showerheaven 970 x 970 10621807 10623807 Showerheaven 720 x 720 10625807 10627807 10751007 10972007 40873000 10651007 6...

Page 7: ...2 1 4 Laminar 3 Rain 5 Body 1 2 3 4 5 7 i...

Page 8: ...DN 20 DN 20 DN 20 DN 20 DN 15 DN 15 DN 15 DN 15 DN 15 28491007 6x 10751007 40872000 10651007 28491007 28491007 28491007 28491007 28486187 40877180 10650187 10750187 DN 20 8 i...

Page 9: ...2 1 3 1 2 3 2 3 4 4 9 i...

Page 10: ...10750187 10650187 40872000 10751007 10651007 Showerheaven 970 x 970 10621807 10623807 Showerheaven 720 x 720 10625807 10627807 DN 20 DN 20 DN 20 1 0 i...

Page 11: ...3 Laminar 2 Rain 4 Body 1 1 2 3 4 11 i...

Page 12: ...10750187 10650187 Rainfall 28411007 DN 20 DN 20 DN 20 DN 20 40872000 10751007 10651007 1 2 i...

Page 13: ...3 Whirl 2 Rain 4 Rainflow 1 1 2 3 4 1 3 i...

Page 14: ...10650187 10750187 Showerheaven 970 x 970 10621807 10623807 Showerheaven 720 x 720 10625807 10627807 10751007 40873000 10651007 DN 20 DN 20 DN 20 1 4 i...

Page 15: ...3 Laminar 2 Rain 4 Body 1 1 2 3 4 1 5 i...

Page 16: ...28486187 10750187 28486187 10751007 28491007 28491007 28491007 28491007 28491007 4x DN 20 DN 20 DN 15 DN 15 DN 15 DN 15 DN 20 DN 20 1 6 i...

Page 17: ...3 2 1 1 2 3 1 2 1 7 i...

Page 18: ...10751007 28491007 1x 10650187 28486187 10750187 28491007 4x 28491007 10651007 28491007 28491007 DN 20 DN 20 DN 20 DN 15 DN 15 DN 15 1 8 i...

Page 19: ...4 2 1 1 2 3 3 4 1 9 i...

Page 20: ...28486187 3x 10750187 10751007 28491007 4x 28491007 27830007 27451007 DN 20 DN 20 DN 15 DN 15 DN 15 28532007 2 0 i...

Page 21: ...3 2 1 1 2 3 2 1 i...

Page 22: ...10751007 28486187 10750187 28491007 4x 27451007 28491007 28491007 28491007 27830007 DN 20 DN 20 DN 20 DN 20 DN 15 DN 15 28532007 2 2 i...

Page 23: ...3 2 1 1 2 3 2 3 i...

Page 24: ...G 3 4 G 3 4 2a 2b 1 3 4 5 1 3 5 5 1 3 6 2 4 2 4 6 SW 12 mm SW 12 mm 2 4...

Page 25: ...min 3 6 2 3 1 G 1 2 G 1 2 G 1 2 80 SW 17 mm SW 17 mm G 1 2 G 1 2 1 1 2 3 3 SW 10 mm AXOR Starck 10650187 2 108 max 2 5...

Page 26: ...Z H E N Flushing of the pipes 12 mm Z H 40878 40877 E N Screw in the plug If there is no shutoff valve behind the basic body 40878 40877 seal the included plug and screw it in This will prevent stagn...

Page 27: ...4 G3 4 48 80 95 48 65 70 80 80 107 80 80 80 103 max min max min G3 4 80 108 133 G3 4 330 342 41 41 41 88 G 1 2 G 1 2 AXOR ShowerCollection 10650187 48 65 75 48 60 25 28 59 18 35 45 101 max min 80 108...

Page 28: ...between the wall and the plastic housing with silicone free of acedic acid EN Apply PCI Lastogum or simi lar sealing compound on the wall in accordance with manufacturers indications Cut sealing coll...

Page 29: ...tion 10750187 94142000 98183000 23x2 5 95334000 97998000 95336000 98181000 18x2 98198000 38x2 5 98198000 38x2 5 92118000 15x1 5 2 9 10658000 94142000 95389000 98183000 23x2 5 98181000 18x2 AXOR Shower...

Page 30: ...3 0...

Page 31: ...3 1...

Page 32: ...AXOR Hansgrohe SE Auestra e 5 9 77761 Schiltach Deutschland info axor design com axor design com 11 2018 9 04829 52...

Reviews: