Product Specification
Max. flow rate
2.2 gpm
Max. incoming water pressure
145 psi
Recommended water pressure
14.5 - 72 psi
Max. hot water temperature
176
o
F*
Recommended hot water temp.
120
o
F - 140
o
F*
Hole size in mounting surface
valves
1 1/4”
spout
1 3/8”
Max. thickness of mounting surface 1 3/8”
Lavatory faucet 18013001 includes 10 mm supply hoses. 10 mm - 3/8” adapters included.
Bidet faucet 18213001 requires 1/2” supply lines (not included)
*Know and follow all applicable local plumbing codes when setting the temperature on the water heater. In Massachusetts,
the water heater may be set no higher than 112
o
F.
Installation
Flush the hot and cold supply lines thoroughly before
installing this faucet.
Install the metal washer and friction washer on the valve.
From below the mounting surface, push the valve up
through the hole (1).
Install the o-ring on the upper mounting plate (2).
Secure the upper mounting plate to the valve by turning it
clockwise.
Lower the valve so that the mounting plate rests on the
mounting surface (1). Tighten the screws (2).