21
TASER Bolt 2 Energy Weapon User Manual
Chapter 6: Maintenance and Care
cycle to run for the full 30 seconds.
9
Shift the safety switch to the rearward (SAFE) position.
10
If necessary, turn training mode off.
Changing the Batteries
To install or change the battery pack:
1
Shift the safety switch to the forward (ARMED) position so the safety cap pops off.
2
Shift the safety switch to the rearward (SAFE) position.
3
Safely remove the Bolt 2 cartridge.
4
To remove the battery pack, slide the battery door off the energy weapon.
5
Replace the batteries.
6
Reinstall the battery pack. Ensure that the battery pack is fully inserted into the Bolt 2 energy
weapon. Failure to do so could result in a damaged energy weapon or a loss of power during
a deployment.
7
Slide the battery door back onto the energy weapon.
8
Perform a function test. See