background image

 

4

 
 
 

GROUNDING INSTRUCTIONS 

 

The appliance must be grounded, if it should malfunction or breakdown, grounding provides a path of least 
resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having 
equipment-ground conductor and grounding plug. The plug must be inserted into an appropriate outlet that is 
properly installed and grounded in accordance with all local codes and ordinances. 
 

WARNING –

 Improper connection of the equipment-grounding conductor can result in a risk of electric 

shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is 
properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet; have a 
proper outlet installed by a qualified electrician.   
 

For grounded, cord-connected appliances: 

This appliance is for use on a circuit having a normal rating more than 120 volt and is factory-equipped with a 
specific electric cord and plug to permit connection to a proper electric circuit. Make sure that the appliance is 
connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance. 
If the appliance must be reconnected for use on a different type of electric circuit, qualified service personnel 
should make the reconnection. 
 

For a permanently connected appliance: 

This appliance must be connected to a grounded metal, permanent wiring system; or an equipment-grounding 
conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead 
on the appliance.   
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 501228

Page 1: ...AT6100DT DowndraftTable AT M 30 04 2019 Code 501228 Original Instructions ...

Page 2: ...s been issued by CHANGTJER MACHINERY CO LTD at NO 600 SEC 4 CHANG PING RD DAYA DIST TAICHUNG 42850 TAIWAN R O C and complies with the relevant essential health and safety requirements 2006 42 EC 2004 108 EC EN ISO 12100 2010 EN 60204 1 2006 AC 2010 declares that the machinery described This machine complies with the following directives EU Declaration of Conformity EN 61000 6 4 2007 A1 2011 Signed...

Page 3: ...CTIONS 4 SPECIFICATIONS 5 CONTENTS OF PACKAGE 6 CONTENTS OF PARTS BAG 7 ASSEMBLY INSTRUCTION 8 EXPLODED DIAGRAM 10 PARTS LIST 11 WARNING Please read this manual carefully before assembly testing and operating WARNING Do not operate this unit until hose or pipe is installed onto the dust inlet port ...

Page 4: ...or which it was not designed 12 WEAR PROPER APPAREL No loose clothing gloves neck ties rings bracelets or other jewelry to get caught in moving parts Non slip footwear is recommended Wear protective hair covering to contain long hair 13 ALWAYS USE SAFETY GLASSES Wear safety glasses Everyday eyeglasses only have impact resistant lenses they are not safety glasses Also use face or dust mask if cutti...

Page 5: ...ing that is burning or smoking such as cigarettes matches or hot ashes 9 USE only as described in this manual 10 DO NOT pull the dust collector by the power cord NEVER allow the power cord to come in contact with sharp edges hot surfaces oil or grease 11 DO NOT unplug the dust collector by pulling on the power cord ALWAYS grasp the plug not the cord 12 DO NOT handle the plug or dust collector with...

Page 6: ...with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician For grounded cord connected appliances This appliance is for use on a circuit having a normal rating more than 120 volt and is factory equipped with a specific electric cord and plug to permit connection to a proper electric circuit Make sure that the appliance is connected to an outlet havin...

Page 7: ...z 1 Phase AMP 6 A Motor Speed 1400 RPM Suction Capacity 1700 CFM Static Pressure 14 8 Inch H2O Impeller Size 9 1 2 Switch Magnetic Switch Overall Dimensions of Unit 1600x650x900 N W BOX 1 220 LBS BOX 2 41 LBS G W BOX 1 269 LBS BOX 2 50 LBS ...

Page 8: ...Sucking Head Set Left 1 NO 22 1 C Sucking Head Set Right 1 NO 22 2 D Left Side Cover 1 NO 15 E Right Side Cover 1 NO 24 F Sucking Board 8 NO 18 G Drawer 2 NO 34 H Filter Net 4 NO 17 I Rubber 144 NO 20 J Stopper 6 NO 19 K Stopper Nut 6 NO 21 L Foot Pad 6 NO 26 31 M Handle 2 NO 11 N Triangular Knob 2 NO 16 ...

Page 9: ...7 CONTENTS OF PARTS BAG FT 1600 NO Description Specification Q TY Part List No A Phillips Head Screw 3 16 x3 8 16 NO 23 B Pin 4 NO 8 C Flat Head Screw 1 4 x5 8 4 NO 10 ...

Page 10: ...ps head screw NO 23 See FIG 1 STEP1 2 Place the pad and accessory NO26 31 to assemble on the machine bottom See FIG 1 2 FIG 1 1 STEP2 1 NO 5 NO 4 NO 32 STEP2 Lift up the left side cover NO 15 and right side Cover NO 24 Use triangular knob NO 16 to fix on the Sucking head set See FIG 2 FIG 2 FIG1 2 ...

Page 11: ...9 FT 1600 Part List ...

Page 12: ...13 Flat Head Screw 5 16 x1 2 8 14 Blower Housing 2 15 Left Side Cover 1 16 Triangular Knob 1 4 x3 8 2 17 Filter Net 4 18 Sucking Board 8 19 Stopper 6 20 Pad 144 21 Stopper Nut PG13 5 6 22 1 Left Sucking Head Set 1 22 2 Right Sucking Head Set 1 23 Phillips Head Screw 3 16 x3 8 16 24 Left Side Cover 1 25 Main Housing 1 26 Washer 1 2 x25x2 6 27 Nut 1 2 6 28 Lock Nut 1 2 6 29 Washer 1 2 x35x3 6 30 Pad...

Page 13: ...r Cord 0 75x4Cx2Mx3T3Y2R 1 37 Phillips Head Screw 3 16 x3 8 1 38 Tapping Screw 4 39 On Off Switch 2 40 Nut 3 16 1 41 Sawtooth Shape Washer M4 1 42 Phillips Head Screw 3 16 x1 2 4 43 Switch Plate 1 44 Switch Box 1 ...

Page 14: ...together with household waste material By law they must be collected and recycled separately EU Countries Only The Axminster guarantee is available on Craft Trade Engineer AirTools CNCTechnology Series machines Buy with confidence from Axminster So sure are we of the quality we cover all parts and labour free of charge for three years For more information visit axminster co uk 3years ...