How to reset to factory default settings
Important
Reset to factory default should be used with caution. A reset to factory default resets all
settings, including the IP address, to the factory default values.
To reset the product to the factory default settings:
1. Disconnect power from the product.
2. Press and hold the control button while reconnecting power. See
3. Keep the control button pressed for 15–30 seconds until the status LED indicator flashes
amber.
4. Release the control button. The process is complete when the status LED indicator turns
green. The product has been reset to the factory default settings. If no DHCP server is
available on the network, the default IP address is
192.168.0.90
5. Use the installation and management software tools to assign an IP address, set the
password, and access the video stream.
The installation and management software tools are available from the support pages
on
www.axis.com/support