AXIS P1365-E Mk II Network Camera
Access the Product
Controls on the Live View Page
Click
View size
to scale the image down to 800 pixels wide or to full scale. Only available in MJPEG.
Click
WDR on
to enable WDR in intense backlight conditions. Click
WDR off
to disable WDR in low
light conditions for optimal exposure.
Select a stream profile for the Live View page from the
Stream Profile
drop-down list. For information
about how to configure stream profiles, see
Click
Pulse
to activate the product’s output port for a defined period of time. For information about how
to enable and configure output buttons, see
. The output button name may differ depending on
the name entered in the I/O Ports configuration.
Click the
Active/Inactive
buttons to manually activate and inactive the product’s output port. For
information about how to enable and configure output buttons, see
The
Manual Trigger
button is used to trigger an action rule from the Live View page. For information
about how to configure and enable the button, see
Click
Snapshot
to save a snapshot of the video image. This button is primarily intended for use when
the AXIS Media Control viewer toolbar is not available. Enable this button from
Live View Config >
Action Buttons
.
The
Audio clip
drop-down list allows you to play an audio clip from the Live View page. Select the
audio clip and click the
Play
button.
Manual Trigger
The
Manual Trigger
is used to trigger an action rule from the Live View page. The manual trigger can for example be used to
validate actions during product installation and configuration.
To configure the manual trigger:
1. Go to
Setup > Events
.
2. Click
Add
to add a new action rule.
3. From the
Trigger
drop-down list, select
Input Signal
.
4. From the second drop-down list, select
Manual Trigger
.
5. Select the desired action and configure the other settings as required.
For more information about action rules, see
To show the manual trigger buttons in the Live View page:
1. Go to
Setup > Live View Config
.
2. Under
Action Buttons
, select
Show manual trigger button
.