Axis I8016-LVE User Manual Download Page 15

AXIS I8016-LVE Network Video Intercom

Troubleshooting

When the upgrade has finished, the product restarts automatically.

Technical issues, clues, and solutions

If you can’t find what you’re looking for here, try the troubleshooting section at

axis.com/support

.

Problems upgrading the firmware

Firmware upgrade failure

If the firmware upgrade fails, the device reloads the previous firmware. The most common reason
is that the wrong firmware file has been uploaded. Check that the name of the firmware file
corresponds to your device and try again.

Problems after firmware
upgrade

If you experience problems after a firmware upgrade, roll back to the previously installed version
from the

Maintenance

page.

Problems setting the IP address

The device is located on a
different subnet

If the IP address intended for the device and the IP address of the computer used to access the
device are located on different subnets, you cannot set the IP address. Contact your network
administrator to obtain an IP address.

The IP address is being used
by another device

Disconnect the Axis device from the network. Run the ping command (in a Command/DOS window,
type

ping

and the IP address of the device):

• If you receive:

Reply from <IP address>:

bytes=32; time=10...

this means that the IP address may already be in use by another device on the network.
Obtain a new IP address from the network administrator and reinstall the device.

• If you receive:

Request timed out

, this means that the IP address is available

for use with the Axis device. Check all cabling and reinstall the device.

Possible IP address conflict
with another device on the
same subnet

The static IP address in the Axis device is used before the DHCP server sets a dynamic address.
This means that if the same default static IP address is also used by another device, there may
be problems accessing the device.

The device can’t be accessed from a browser

Can’t log in

When HTTPS is enabled, ensure that the correct protocol (HTTP or HTTPS) is used when attempting
to log in. You may need to manually type

http

or

https

in the browser’s address field.

If the password for the user root is lost, the device must be reset to the factory default settings.
See

Reset to factory default settings on page 14

.

The IP address has been
changed by DHCP

IP addresses obtained from a DHCP server are dynamic and may change. If the IP address has been
changed, use AXIS IP Utility or AXIS Device Manager to locate the device on the network. Identify
the device using its model or serial number, or by the DNS name (if the name has been configured).

If required, a static IP address can be assigned manually. For instructions, go to

axis.com/support

.

Certificate error when using
IEEE 802.1X

For authentication to work properly, the date and time settings in the Axis device must be
synchronized with an NTP server. Go to

System > Date and time

.

The device is accessible locally but not externally

To access the device externally, we recommend you to use one of the following applications for Windows

®

:

• AXIS Companion: free of charge, ideal for small systems with basic surveillance needs.
• AXIS Camera Station: 30-day trial version free of charge, ideal for small to mid-size systems.

For instructions and download, go to

axis.com/vms

.

15

Summary of Contents for I8016-LVE

Page 1: ...AXIS I8016 LVE Network Video Intercom User Manual...

Page 2: ...or events 12 NAT traversal 13 Applications 13 Troubleshooting 14 Reset to factory default settings 14 Check the current firmware version 14 Upgrade the firmware 14 Technical issues clues and solutions...

Page 3: ...eo Intercom Setup overview Setup overview 1 Intercom 2 Intercom combined with AXIS A9801 3 Intercom combined with AXIS A9161 4 Intercom combined with a reader and an access control system for example...

Page 4: ...indicator icons on page 20 2 Camera 3 Call button 4 IR illuminator 5 Speaker 6 Microphone 7 I O connector on page 21 8 Control button on page 20 9 Audio connector on page 21 10 Status LED 11 SD card...

Page 5: ...and enter the IP address or host name of the Axis device If you do not know the IP address use AXIS IP Utility or AXIS Device Manager to find the device on the network 2 Enter the username and passwor...

Page 6: ...ection and then change the password The device password is the primary protection for your data and services Axis devices do not impose a password policy as they may be used in various types of instal...

Page 7: ...public network or the internet we recommend you not to allow incoming calls 3 Click Call handling 4 In Calling timeout set the number of seconds that a call will last before it ends if there is no ans...

Page 8: ...a Name for the account 4 Select Registered 5 Select a transport mode 6 Add the account information from the PBX provider 7 Click Save 8 Set up the SIP settings in the same way as for peer to peer see...

Page 9: ...from the intercom the person who answers can use the Dual Tone Multi Frequency signaling DTMF of his SIP device to unlock the door The door controller unlocks and locks the door This example explains...

Page 10: ...t in low light conditions by using night mode Your camera uses visible light to deliver color images during the day But as the visible light diminishes color images become less bright and clear If you...

Page 11: ...n a recipient replies a call is established The voice and video is transferred through VoIP technologies Session Initiation Protocol SIP The Session Initiation Protocol SIP is used to set up maintain...

Page 12: ...The PBX SIP server can be set up as a local entity or offsite It can be hosted on an intranet or by a third party provider When you make SIP calls between networks calls are routed through a set of PB...

Page 13: ...tocol increases the chances of finding the most efficient path to successful communication between peer devices If you also enable STUN and TURN you improve the ICE protocol s chances STUN STUN Sessio...

Page 14: ...ory default and click Default Check the current firmware version Firmware is the software that determines the functionality of network devices When you troubleshoot a problem we recommend you to start...

Page 15: ...all cabling and reinstall the device Possible IP address conflict with another device on the same subnet The static IP address in the Axis device is used before the DHCP server sets a dynamic address...

Page 16: ...ng of different streams resolution compression by different clients affects both frame rate and bandwidth Use identical streams wherever possible to maintain a high frame rate Stream profiles can be u...

Page 17: ...k relay state go to System Accessories and find the relay port 2 Set Normal state to for a fail secure lock for a fail safe lock Relay powered by separate power supply 1 To check relay state go to Sys...

Page 18: ...to System Accessories and find the relay port 2 Set Normal state to for a fail secure lock for a fail safe lock 12V Fail secure lock powered by PoE from intercom 1 To check relay state go to System Ac...

Page 19: ...deo Intercom Connect equipment 12V Fail secure lock powered by external power supply 1 To check relay state go to System Accessories and find the relay port 2 Set Normal state to for a fail secure loc...

Page 20: ...use sharp tools metal objects or excessive force when inserting or removing the SD card Use your fingers to insert and remove the card Risk of data loss and corrupted recordings Do not remove the SD...

Page 21: ...ectors Digital output For connecting external devices such as relays and LEDs Connected devices can be activated by the VAPIX Application Programming Interface through an event or from the product s w...

Page 22: ...ould result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NO NO NOTICE TICE TICE Indicates a situation which if not a...

Page 23: ...User Manual Ver M6 4 AXIS I8016 LVE Network Video Intercom Date February 2022 Axis Communications AB 2020 2022 Part No T10154915...

Reviews: