![Axis F44 User Manual Download Page 73](http://html.mh-extra.com/html/axis/f44/f44_user-manual_3038308073.webp)
AXIS F41 Main Unit
Technical Specifications
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant
limited power source (LPS) with either a rated output power limited to
≤
100 W or a rated output
current limited to
≤
5 A.
Audio Connector
3.5 mm audio connectors
(stereo)
1 Tip
2 Ring
3 Sleeve
Audio Input
Microphone/Line in
Balanced: ‘Hot’ signal Microphone/Line in
Unbalanced: Microphone/Line in
Balanced: ‘Cold’ signal Microphone/Line
in
Unbalanced: Unused
Ground
Audio Output
Line out, mono (stereo connector
compatible)
Line out, mono (stereo connector
compatible)
Ground
The internal microphone is used by default; the external microphone is used when connected. It is possible to disable the internal
microphone by connecting a plug to the mic input.
Connection Diagrams
I/O Connector
1
2
3
A
B
D
S
G
1
0 V DC (-)
2
DC output 12 V, max 50 mA
73