Specifications

Function

Pin

Notes

Specifications

DC ground

1

0 V DC

DC output

2

Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.

12 V DC
Max load = 50 mA

Input 1

3

Digital input or Supervised input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate. To use supervised input,
install end-of-line resistors. See connection diagram for information
about how to connect the resistors.

0 to max 30 V DC

Output 1

4

Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.

0 to max 30 V DC, open drain,
100 mA

Input 2

5

Digital input or Supervised input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate. To use supervised input,
install end-of-line resistors. See connection diagram for information
about how to connect the resistors.

0 to max 30 V DC

Output 2

6

Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.

0 to max 30 V DC, open drain,
100 mA

1

DC ground

2

DC output 12 V, max 50 mA

3

Supervised input port 1

4

Digital output port 1

5

Supervised input port 2

6

Digital output port 2

Power connector

2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to

100 W or a rated output current limited to

5 A.

22

Summary of Contents for ExCam XF P1377

Page 1: ...S P13 Network Camera Series AXIS P1375 Network Camera AXIS P1377 Network Camera AXIS P1378 Network Camera ExCam XF P1377 Explosion protected Camera F101 A XF P1377 Explosion protected Camera User Manu...

Page 2: ...es with strong backlight 9 Show a text overlay in the video stream when the device detects motion 10 Video compression formats 11 Reduce bandwidth and storage 12 Set up network storage 12 Add audio to...

Page 3: ...in microphone 4 Zoom puller 5 Lock screw for focus ring 6 Focus ring 7 Power connector DC 8 T92G20 connector 9 Control button 10 RS485 422 connector 11 I O connector 12 i CS connector compatible with...

Page 4: ...e device has its original Axis firmware or to take full control of the device after a security attack 1 Reset to factory default settings See Reset to factory default settings on page 16 After the res...

Page 5: ...document www axis com products online manual 43168 t10098905 Support tip Password security confirmation check 1 Type a password Follow the instructions about secure passwords See Secure passwords on p...

Page 6: ...onnect the lens cable 4 Reconnect the power 5 Log in to the product s webpage go to the Image tab and then select the P Iris lens you have installed Note If you use a DC iris lens select Generic DC Ir...

Page 7: ...wn the shutter speed set max shutter to the highest possible value Reduce sharpness in the image Note When you reduce the max gain the image can become darker Set the max gain to a lower value Open th...

Page 8: ...e corridor format to better utilize the full field of view in a long and narrow area for example a staircase hallway road or tunnel 1 Depending on your device turn the camera or the 3 axis lens in the...

Page 9: ...m within it By using view areas you can remove parts of the full view for example the sky When you set up a view area we recommend you to set the video stream resolution to the same size as or smaller...

Page 10: ...xtra information during recordings such as a timestamp or during product installation and configuration You can add either text or an image Show a text overlay in the video stream when the device dete...

Page 11: ...l video sequence that is made up of a series of individual JPEG images These images are then displayed and updated at a rate sufficient to create a stream that shows constantly updated motion For the...

Page 12: ...c FPS Note Web browsers do not support H 265 decoding Use a video management system or application supporting H 265 decoding Set up network storage To store recordings on the network you need to set u...

Page 13: ...n action 1 Go to Settings System Events to set up a rule The rule defines when the device will perform certain actions Rules can be setup as scheduled recurring or for example triggered by motion dete...

Page 14: ...uffer time to 60 seconds 8 In the list of storage options select SD card 9 Click Save Applications AXIS Camera Application Platform ACAP is an open platform that enables third parties to develop analy...

Page 15: ...etwork Camera Series Additional settings To watch this video go to the web version of this document www axis com products online manual 43168 t10001688 How to activate an application licence code on a...

Page 16: ...either the active track or the long term support LTS tracks Being on the active track means continuously getting access to all the latest product features while the LTS tracks provide a fixed platfor...

Page 17: ...product as an administrator 3 Go to Settings System Maintenance Follow the instructions on the page When the upgrade has finished the product restarts automatically Technical issues clues and solutio...

Page 18: ...when using IEEE 802 1X For authentication to work properly the date and time settings in the Axis device must be synchronized with an NTP server Go to Settings System Date and time The device is acces...

Page 19: ...t H 264 clients affects the bandwidth Simultaneous viewing of different streams resolution compression by different clients affects both frame rate and bandwidth Use identical streams wherever possibl...

Page 20: ...t Note Only valid for optional P iris DC iris or manual iris lenses The status LED flashes when the Focus Assistant is active Color Indication Red The image is out of focus Adjust the lens Amber The i...

Page 21: ...ne with or without electret power or line Electret power if selected Ground Audio output 1 Tip 2 Ring 3 Sleeve Channel 1 unbalanced line mono Channel 1 unbalanced line mono Ground For audio in the lef...

Page 22: ...max 30 V DC open drain 100 mA Input 2 5 Digital input or Supervised input Connect to pin 1 to activate or leave floating unconnected to deactivate To use supervised input install end of line resistors...

Page 23: ...22 simplex Four wire RS422 full duplex point to point communication Function Pin Notes RS485B alt RS485 422 RX B 1 RS485A alt RS485 422 RX A 2 RX pair for all modes combined RX TX for 2 wire RS485 RS4...

Page 24: ...User Manual Ver M5 4 AXIS P13 Network Camera Series Date May 2021 Axis Communications AB 2019 2020 Part No T10135685...

Reviews: