AXIS D2050-VE Network Radar Detector
•
Calibration using pins
: The calibration is performed in the web interface by dropping
pins in know locations in the reference map and setting the distance between the pins.
When calibrating using pins, you need to select the mounting position of the radar
module inside the detector.
•
Calibration using tracks
: The calibration method requires a person to move in front of
the radar.
You can do this yourself while accessing the web interface from a mobile device, or have
someone else move and follow your instructions.
When moving around in the different steps, move to places that are easy to find in
the reference map.
How to configure the detector
1. To upload a reference map, go to
Settings > Radar > Reference map
. Select
Browse
to
find an image file, and select
Upload
to place the image in the live view.
2. To calibrate the reference map, go to
Settings > Radar > Reference map calibration
.
Select
Start calibration
and follow the instructions.
How to install multiple detectors
If two radar detectors of are mounted close together they may interfere with each other. To avoid
problems, select different channels for the detectors.
1. Go to
Settings > Radar > General
and select
Channel
.
17
EN
Summary of Contents for D2050-VE
Page 1: ...AXIS D2050 VE Network Radar Detector Installation Guide ...
Page 2: ......
Page 26: ...26 ...
Page 44: ...44 ...
Page 48: ...48 ...
Page 66: ...66 ...
Page 70: ...70 ...
Page 88: ...88 ...
Page 92: ...92 ...
Page 110: ...110 ...
Page 114: ...114 ...
Page 136: ...136 ...
Page 155: ...AXIS D2050 VE Network Radar Detector 仅应更换上同型号的电池 应根据当地法规或电池制造商的说明处理废电池 155 ZH ...