AXIS D2050-VE Network Radar Detector
Product overview
Product overview
1
Relay connector
2
Grounding screw
3
Network connector
4
Radar module
5
Intrusion alarm switch
6
Control button
7
I/O connector
8
microSD card slot
9
Power LED
10 Status LED
11
Network LED
Where to install the product
The detector is intended for monitoring open areas. Any solid object (such as a tree or a bush) in the coverage area will create a
blind spot (radar shadow) behind it.
Install the detector on a pole, or on a spot on a wall where there are no other objects or installations close to it.
To be able to correctly identify movement in the coverage area, the detector needs to be installed on a stable mount. Do not
install the detector on a swaying pole.
If two radar detectors of are mounted close together they may interfere with each other, see
How to install multiple detectors on
page 9
.
At the recommended mounting height, the near detection limit is 4.5 m (15 ft).
If there are a lot of metal objects in the field of view there will be a lot of reflections impacting the performance.
Note
Do not repaint the detector. The paint may seriously impact the detector’s performance.
4