OPERATION MANUAL BD/TL
13
__________________________________________________________________________________________________________________
10.
Operation rules during work with accumulators (batteries)
1.Scale can be powered from ~230V supply through feeder attached with scale.
Moreover accumulators, which are placed in container inside the scale, can be
used for powering. Ordinary batteries can be used as well.
2.In order to make accumulators (batteries) discharging time longer, automatic
switching off display backlight and later the whole scale further is possible
during breaks in weighing. Configuration of these mechanisms is done using
b_LIGHT
and
Auto OFF
functions.
3.Charging accumulators is performed automatically after connecting feeder to
the scale, also during weighing. Accumulator power level can be read using
bAttErY
function (
bat LEVEL
option).
When using batteries in place of accumulators, charging during
work with feeder have to be switched off.
bAttErY
function is used
for this purpose (
bAt OFF
option), which is described in further
part of manual. Charging batteries can cause their breaking and
serious damage of the scale.