AXIS Q7401 Video Encoder
6-pin configurable terminal block
Function
Pin
Notes
Specifications
0 V DC (-)
1
DC ground
0 V DC
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC
Max load = 50 mA
Digital input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate.
Min input = - 40 V DC
Max input = + 40 V DC
Configurable
(Input or
Output)
3–
6
Digital output – Connected to pin 1 when
activated, floating (unconnected) when
deactivated. If used with an inductive load, e.g. a
relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
Max load 50 mA
Max voltage =
+ 40 V DC
Open drain
1
0 V DC (-)
2
DC output 12 V, max 50 mA
A
I/O configured as input
B
I/O configured as output
15